At 24 MHz, the clock period is about 41.67 ns. Even at a nominal 50% duty cycle, subtracting a 5 ns rise time from half the period does not give the receiver's effective high time. If 5 ns is defined from 10% to 90% of the output swing, it gives neither the falling transition nor the receiver's actual decision threshold.
Put both cursors at the same threshold
Measure the waveform near the receiver pin. For a guaranteed high-level interval, use the time between crossing the specified VIH on the rising edge and crossing it again on the falling edge. Obtain the low-level window separately at the specified VIL. If the chip defines input pulse width at a different reference level, follow that definition.
If the edges are too slow, record the input, trace, and probe capacitances in the test conditions and repeat with a lower-capacitance probe. Ask the supplier for maximum rise and fall times at the specified supply voltage and load, including the measurement thresholds. Save those conditions alongside the shortest measured pulse width to determine whether the driver or the board load is limiting performance.