When a schematic shows both 27 MHz and 1000/1001, trace the clock tree. Identify the input driven by the external oscillator and the stage that applies the fractional ratio. If the chip synthesizes a fractional output from an integer-frequency reference, order the required integer-frequency part. Ask for a fractional-frequency part when the input itself requires that reference.
27 MHz × 1000/1001 ≈ 26.97302697 MHz. This is about −26.973 kHz, or −999 ppm, relative to 27 MHz. A normal oscillator tolerance of a few tens of ppm cannot cover this nominal difference.
Have the hardware team approve the input, PLL, and target output frequencies together to avoid applying the fractional correction twice. Include both the exact ratio and its readable decimal equivalent in the quote request. Ask the supplier to state the nominal frequency they can deliver. If the final digit has to be rounded, calculate the rounding error relative to the exact fractional target and assess it together with initial frequency accuracy and stability across the operating temperature range.