If the purchase order says only “32K,” enter the complete frequency. Since 32,768 = 2¹⁵, an input of 32,768 Hz yields exactly 1 Hz after 15 ideal divide-by-two stages. With an incorrect 32,000 Hz input and the same divider setting, the output is only 32,000 ÷ 32,768 = 0.9765625 Hz.
Under that assumption, after one actual minute the divider has completed about 58.594 of its one-second cycles. After one actual hour, the indicated time is about 84.375 s behind. An error of this size calls for checking the oscillator frequency and divider settings first. Fine adjustment in ppm cannot replace verification of the basic frequency.
The purchase order should also identify which device generates the clock
Match a passive tuning-fork crystal to the on-chip oscillator circuit using CL, ESR, and permitted drive. For an active clock, check the receiver's external clock input conditions, logic levels, and supply. An RTC module with a built-in oscillator is a separate kind of part. Specify the frequency as 32.768 kHz or 32768 Hz, and identify the device type in the BOM. Epson FC-135 tuning-fork crystal data