PHY reference clocks: what changes when the PHY supplies 50 MHz?

The LAN8720A supports two signal directions for the 50 MHz RMII reference. Trace back from the MAC's REF_CLK input to see whether an external clock source supplies it or the PHY drives it through REFCLKO. In the latter mode, the multiplexed nINT/REFCLKO pin outputs the clock, so its nINT interrupt function is unavailable.Microchip LAN8720A data sheet

Test both a reset and a cable disconnect

Perform a complete power-up or hardware reset. Record the order in which the configuration straps are sampled, reset is released, the reference clock stabilizes, and the MAC starts. In external-input mode, check when the external clock becomes available. In PHY-output mode, verify the configuration and actual signal direction, and check whether the original interrupt net is still connected to the multiplexed pin.

Then unplug and reconnect the Ethernet cable. Compare the PHY status registers with events reported by the driver. If the reference waveform is correct but software is slow to report link loss, check whether the driver is still waiting for the original interrupt. If the driver uses polling instead, specify the status to read, the polling interval, and the response time. This pin restriction applies to the relevant LAN8720A mode. Check the data sheet for other PHYs.

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.