Suppose a 26 MHz TCXO's frequency increases by 5.2 Hz when its supply rises from 2.80 V to 3.00 V. Across that 0.20 V interval, the relative change is +0.2 ppm and the average slope is about +1 ppm/V. Both voltages must be within the part's rated range and measured at the device pins.
Return the voltage to the lower setting
Hold the load, airflow and frequency reference constant. Allow the part to reach thermal equilibrium before each reading, first at the lower voltage, then at the higher voltage and then back at the lower voltage. If the final reading is still almost 5 Hz above the first, that difference is nearly as large as the entire change during the upward step. Check temperature and the timebase before reporting a pushing coefficient of +1 ppm/V that would include slow drift.
If the measurements repeat reliably in both directions, add intermediate and endpoint measurements for the system's static budget. With the local model above, a slow supply change of 20 mV corresponds to about 0.02 ppm, or 0.52 Hz. Switching ripple has its own frequency and coupling path, so check the relevant spectrum. The DC slope alone cannot establish phase noise. Supply and stability conditions for a specific Epson TG2520SMN ordering option