A frequency counter may still read 125 MHz after P and N are swapped on a 125 MHz differential clock. To determine the system impact, find out which receiver edge samples each data word.
At an ideal 50% duty cycle, the period is 8 ns. The original falling edge becomes the rising edge after inversion, 4 ns from the original rising edge. At an actual duty cycle of 45%, only 3.6 ns separates the original rising and following falling edges, with 4.4 ns for the other interval. Using a fixed 4 ns timing correction can underestimate the error.
For a reference-only input, check the chip's stated polarity requirements. For a clock that travels with data, capture both with a common trigger and mark the new sampling point against the setup and hold window. If the receiver can invert polarity, also verify when that setting takes effect during reset.
Acceptance depends on how the clock is used. Record the polarity configuration, initial training, multichannel synchronization and results with data active. A counter alone or a clock running without data does not expose the sampling point. For a concrete example, the AD9265 LVDS output puts different data bits on different DCO edges, so assess the clock and data together. Analog Devices AD9265 data output timing