A quotation that displays 3.579545 MHz as 3.58 MHz can mean the system displays only two decimal places, or the supplier intends to ship a part with a different nominal frequency. The fastest way to tell is to request the complete ordering code and the specification page that states the nominal frequency. The display precision alone does not decide suitability for substitution.
Convert all three values to the same unit
- 3.579545 MHz is 3,579,545 Hz, the design target in this example.
- 3.5795 MHz is 3,579,500 Hz, or 45 Hz below target, approximately −12.57 ppm.
- 3.58 MHz is 3,580,000 Hz, or 455 Hz above target, approximately +127.11 ppm.
Suppose the design allocates only ±20 ppm to the clock source under the specified conditions, equivalent to about ±71.59 Hz. A 3.58 MHz candidate exceeds that window even at its own nominal frequency. The other candidate is offset by only 45 Hz, but has about 26.59 Hz of margin in the downward direction. The part’s own initial tolerance and any other deviations required by the design must fit within this budget. All three frequencies are nominal values. This calculation is not a measurement of any sample.
Which field should receiving inspect?
If both the manufacturer's order and specifications say 3.579545 MHz and the quoting system rounds the display, ask the supplier to include the exact value in hertz in the order notes. If the specification says 3.58 MHz, assess it as a new part number. Waiting until a production counter displays only “3.58 M” leaves the two parts indistinguishable and makes the agreed precision hard to reconstruct.
If a downstream PLL is expected to compensate for the difference, verify its capture range, available adjustment step, and residual error after compensation. Engineering can then approve the approximate frequency.