A radio wants to reuse a small-swing reference, and a supplier lists only “0.4 V typical output.” Nordic recommends an external-clock signal greater than 0.4 V peak for lower current and better signal-to-noise ratio on nRF24L01+. Peak amplitude differs from the peak-to-peak convention common in oscillator quotes. The recommendation is not a universal digital input threshold for every waveform.
Convert the amplitude convention, then check DC conditions
For a sine wave symmetric about its midpoint, 0.4 V peak to peak gives only 0.2 V peak, while 0.4 V peak gives 0.8 V peak to peak. If the quote is RMS, convert using the actual waveform. The sine wave relation cannot be applied indiscriminately to square or clipped waves. Check coupling, supply, and allowed input range. Adequate AC swing does not ensure the waveform remains within allowed limits.
The manufacturer's external-clock diagram drives XC1 and leaves XC2 unused, which may be left open as specified. Measure at the receiver pin after routing and the coupling network, and record probe loading, supply, DC midpoint, peak, and peak-to-peak amplitude. If the source is another chip's oscillator circuit, verify its allowable load and compare source operation before and after connecting. Sharing a clock should not compromise both sides.
Compare radio reception and system current under the same radio settings, temperature, and test position for the external source and the original dedicated crystal. Request the amplitude convention, guaranteed conditions, and load. List recommended performance conditions separately from actual input limits so sample disposition has a clear basis.Nordic nRF24L01+ external-clock guidance