A legacy board needs one oscillator for two clocks. The RFQ lists only frequencies A and B. The SaRonix-eCera NX72SA documentation identifies pin 1 as output enable and pin 2 as FS. Low selects Frequency 1 and high selects Frequency 2. Determine the A/B mapping when ordering. Quotes can offer the same pair in reverse order and start the equipment at the wrong frequency.
Have hardware specify the startup default first
Check whether an external resistor, controller or other circuit drives FS between power-on and software takeover, and whether power sequencing leaves it undefined. Put the default logic level and required startup frequency together, then list the second software-selected frequency. If abnormal pulses are unacceptable during switching, check for an explicit guarantee for the configuration. A static selection table does not establish glitch-free switching.
Include a truth table with the sample request
For each FS and OE combination, record the expected output, whether the receiving module can be held in reset and where to measure. On the first samples, verify both steady-state frequencies while the receiver remains in reset, then observe switching transients and recovery as required by the application. Save actual supply, load and bandwidth with the full order configuration and sample ID.
If repair staff have only seen one output frequency, check legacy firmware and board pull resistors to see whether the other setting was used. Confirm availability, price and lead time with the supplier for the exact configuration. An archived datasheet explains the pins and cannot establish current availability of a given frequency pair. Archived Diodes NX72SA datasheet