A card with one oven-controlled oscillator starts normally on the bench. In the chassis, two identical cards start together and one clock comes and goes. A current measurement taken after both cards are warm misses the period that matters. Look at the voltage actually reaching each oscillator while the heaters are drawing startup power and the regulator may be current limiting.
Page 2 of the Microchip OX-221 datasheet lists a 3.135 to 3.465 V standard supply range, a 4.0 W maximum warm-up consumption, and a 1.35 W maximum steady-state consumption at 25 °C. Keep the power figure, temperature, and supply range in separate fields on the acceptance sheet. The room-temperature steady-state figure does not specify steady consumption under all cold conditions. Confirm the configuration and electronic tuning option for each offered part before comparing quotes and reports.
Estimate the demand while both heaters are on
For two devices on a nominal 3.3 V rail, 4.0 W divided by 3.3 V corresponds to about 1.21 A for each device and 2.42 A together. With another 0.30 A for logic and interfaces, the estimate rises to 2.72 A. A supply rated for 2.5 A continuous output needs a closer look at duration, actual current, and its protection behavior. In contrast, the 25 °C steady-state figure gives about 0.41 A per device, or 1.12 A for the two devices and logic together. Both calculations are useful at different points in the startup sequence.
This calculation provides a starting point for rail sizing. Dividing the datasheet power by nominal voltage gives no current waveform. Ask for peak current, duration, and cold test conditions where the system relies on them. Define the cold soak, the number of cards starting together, and the input range before sending the same question to the regulator and oscillator suppliers. A typical waveform belongs in the engineering evidence, with the contractual limits stated separately.
The voltage at the regulator output can look adequate while the oscillator sees less. Suppose the regulator delivers 3.30 V and the shared supply and return have 45 mΩ of combined resistance. At 2.72 A their drop is about 0.122 V. If the branch for one device drops another 0.055 V at 1.21 A, the device sees about 3.123 V, below 3.135 V. The drop falls once both devices warm up. Use measured shared and branch drops in the actual design and leave room for regulator tolerance and transient response.
Establish the sequence on a real cold start
Capture regulator output, voltage across the oscillator supply and ground pins, current, and a clock-valid indication on the same acquisition. A stable regulator output with a dip at the oscillator sends the investigation toward the connectors, copper, returns, and card distribution. A dip at both ends with repeated charges and discharges warrants a check of the regulator's limit and automatic restart behavior.
Record continuous clock output, entry into the allowed frequency window, downstream reset release, and the system-ready indication separately. An output waveform may appear before downstream input thresholds or frequency rules are met. Follow the cold soak and starting condition for the relevant warm-up specification. A reboot after a few seconds of power-off can leave the oven warm inside even when the outside case feels similar.
Compare simultaneous and staged starts
For simultaneous startup, check actual total current, minimum pin voltage, and latest readiness. If the second oscillator starts only once the first heater load has declined, account for both the coldest condition and the evidence that the first device really left its high-current stage. A fixed timer can release the second load too early. A current-based release requires a persistence threshold and a defined fault response if the current fails to fall. Ask whether the standby clock must be ready at the same instant as the main clock.
Also measure a sequence with a short gap between starts. The first oscillator still draws steady-state current, and adding the second heater then produces a different load from the all-cold case. Keep card position, serial number, supply setting, soak, and restart interval with the captures. Change one condition, such as the supply distribution or order, to see whether the low point follows the card or its slot. For a different regulator, check current-limit recovery, capacitive startup, and heater demand individually.
The purchase request can state the real case in a sentence: two devices share the rail and must start at the agreed minimum temperature. Ask for the warm-up power, operating voltage, and test conditions for the offered configuration. Preserve both pin-voltage traces and the system-ready time in acceptance records so the next alternative can be evaluated against the same requirements.