A low-noise OCXO quote includes a short-term stability plot. Micro Crystal's OCXOVS 10 MHz example is measured at 25 °C in still air, without vibration, at rated supply, and documents the reference and setup. Variable-speed enclosure fans may intermittently direct cool air over the board. The plot illustrates the manufacturer method but does not establish stability in that enclosure. Define both the comparison curve and final operating conditions in the RFQ.
Separate airflow changes from ambient enclosure temperature
Document oscillator position relative to ducts, baffles, and heat sources and whether fan control is fixed, cyclic, or temperature-based. Put both candidates in equivalent locations, establish a still-air baseline at the same warm-up, supply, and reference, then use the target fan strategy. Alternating between the inlet and a sheltered position confounds enclosure and device differences. When practical, record local temperature over time rather than only the enclosure setpoint.
Request comparable data from suppliers
Define averaging time, statistic, record length, detrending, and reference capability. Slow drift due to airflow can appear at longer averaging times. Quoting only the curve's minimum can omit the range used for synchronization. If a supplier provides only typical still-air data, mark that limitation and make enclosure airflow testing a separate sample-stage task.
If placement or baffles improve results, put the change in production drawings. A device change also requires review of thermal design and warm-up. The reproducible approval conditions should specify supply, mounting, and fan behavior, along with the averaging time for the stability figure. Micro Crystal OCXOVS 10 MHz short-term stability bench example