Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Both SG-8002CE options use 5 V. Why do PT and PH need different duty-cycle tests?

A maintenance order calls for a 5 V oscillator at the original frequency. The new quote says SG-8002CE, and repair asks whether PT and PH can be interchanged. Separate power supply, output load, and the duty-cycle measurement. Copying a 45% to 55% range gives little protection if the laboratory and receiving station use different loads and thresholds.

H and T identify different output conditions

Epson's programmable oscillator guide lists H as 5.0 V CMOS with a 50% VDD duty threshold and T as 5.0 V TTL referenced to 1.4 V. In the SG-8002 outline, P and S identify enable and standby respectively. For SG-8002CE, PT/ST and PH/SH appear in different rows. PT/ST specifies a TTL load at 4.5–5.5 V. PH/SH specifies CMOS capacitive loads within the same supply range, with further frequency and temperature conditions. Recover both the feature and the output option from a label or purchasing record. A photo of the body and frequency does not establish the full part.

Add the receiving device and application to the comparison. Include its input thresholds, minimum pulse widths, output state during disable, restart delay, and board load. The oscillator specification uses a prescribed test load. The receiving device has its own voltage requirements. Have engineering confirm which pairing fits. An offer stating both parts use five volts establishes only the supply.

Work through a 25 MHz example

The 25 MHz period is 40 ns. Epson's outline includes 45% to 55% SG-8002CE symmetry rows covering the appropriate 25 MHz and temperature conditions for PT/ST with its TTL load and PH/SH with its CMOS load. At 40 ns that range corresponds to 18–22 ns. TTL uses a 1.4 V crossing, while the CMOS threshold at 5 V is 2.5 V. Check the exact applicable row for grade and load, including whether a 15 pF or a 25 pF entry applies.

As an illustration, one waveform can give different widths at those thresholds. If its 1.4 V rise and fall crossings occur at 2 and 23 ns, its high pulse is 21 ns, or 52.5%. If 2.5 V crossings occur at 3 and 20 ns, it reads 17 ns, or 42.5%. These hypothetical readings demonstrate the calculation. A single capture can move inside or outside the indicated window when the threshold changes, so preserve both threshold and load in the acceptance plan.

Check the supplier's test and the actual board

Record supply, output option, load, and scope threshold. Save the waveform and directly measured high and low widths for each option. Compare with the datasheet at its conditions. Then measure at the board receiver with the threshold and pulse limits it needs. A counter at the oscillator pin can show a steady frequency while a receiver misses pulses. Check levels and overshoot when supply, cabling, or loading changes. Document how any automatic scope duty measurement sets its crossing.

Also test disable and recovery if the board uses a control pin. For an older BOM with only a family name, compare a known-good board’s power and control signals with the original order. If the supplier proposes a different family, check its actual output and conditions against the board. Write problematic conditions into the test record so the supplier can reproduce them with the matching threshold and load.

Compare the acquisition interval on two reports as well. Records can contain startup transitions. Check steady-state symmetry at its stated conditions and record trigger time, averaging, and per-cycle extremes. Where a repair board has reset or startup requirements, capture the transition from disabled to running separately so control timing can be distinguished from the output option.

Make the order identify the exact specification row

Record the complete ordering code, frequency, 5 V supply, P or S function, T or H output, temperature range, and packaging. Keep the load and threshold with the percentage check. Review any discontinuation notices against the actual voltage variant. Hold the original and alternative under distinct part records until the applicable datasheet tests and receiver requirements are both confirmed for the approved application.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.