Supplier A quotes a FIT figure. Supplier B reports zero failures in accumulated testing. Entering zero in the FIT comparison misstates the second result. FIT expresses expected failures per billion device operating hours. Zero failures is what one group of samples showed over a finite test. Estimating a failure rate also requires sample count, accumulated device-hours, confidence level, and conditions of use.
Reconstruct the denominator in the manufacturer's report
SiTime AN10025 shows how to use accumulated test time, zero observed failures, and a confidence level, then apply an acceleration factor to estimate conditions of use. When reviewing reports attached to a quote, record tested products, temperature, device-hours, observed failures, and report revision in separate fields. Two reports can both show zero failures, yet different device-hours can give different statistical upper bounds. For a series-level test, document why it applies to the purchased part.
Distinguish operating hours, product service life, and warranty period
Use a hypothetical example to make the calculation easy to follow. At 1 FIT, 100,000 units with one device each and 1,000 operating hours per unit accumulate 100 million device-hours. Assuming a constant failure rate, the expected number of failures is 0.1. This is a population expectation. It does not predict a failure date for any one unit. If the equipment contains multiple devices, a reliability engineer should model the system using its architecture and operating conditions.
Retain “no comparable result provided” as a status in the supplier assessment. Ask supplier B for the applicable manufacturer report and supplier A to identify the part and conditions behind its number. Use the contract terms for service replacement periods and compensation. This keeps a statistical forecast from becoming a warranty commitment. SiTime AN10025 reliability calculation guidance