AOI sees no side fillet after an oscillator change. Do you reject the parts or change the program?

Two oscillators fit an existing PCB land pattern. After reflow, the original has solder visible at each corner. The alternative shows only a bright edge and triggers optical opens. Investigate side wetting and the actual bottom joint separately. The images alone cannot identify termination geometry, paste printing, placement, oven profile, or the AOI program as the cause.

Verify the termination and ordering option

NXP's QFN and SON assembly guide illustrates pullback terminals, exposed ends, and steps or dimples designed to improve wetting. The geometries provide different side-visible features. A wettable flank promotes a solder fillet suitable for optical inspection. NXP also identifies paste, stencil, board design, and reflow as influences on the fillet. Check the oscillator's exact package drawing for specified plating and wettable side length. A bright copper edge is insufficient evidence of a designed wettable flank.

Have the supplier state which view the drawing presents and where terminal metal and finish end. If the side is an inspection surface, add that requirement to the approved drawing and ordering code. If only one option in the family carries it, block the others in ordering and inventory. Ask the manufacturer about construction where the only available drawing shows the land pattern. SiTime's manufacturing notes also refer buyers to device datasheets for mechanical drawings, so check the complete number before assembly.

Use controlled trial boards to isolate the difference

Use the same PCB lot, paste, stencil, and reflow process to compare original and alternative parts. Track which board holds each sample and its reel. Check paste thickness and coverage, then photograph terminals before placement and the side view after reflow. Examine omissions, placement offsets, and obstructed camera views. Spread matched positions across trial boards where possible to avoid putting one group in a colder position.

A pullback terminal can lack a visible side fillet while its bottom joint is sound. Quality can choose applicable X-ray, a cross section, or another approved validation method based on the project. If the same pin flags repeatedly, check whether the geometry limits visibility. If calls cluster on one region of the panel, look at paste, contact, and reflow conditions. Use the manufacturer's drawing to interpret the result. A darker image or relaxed threshold can conceal a real assembly problem.

Bound the finding before disposition

Suppose 40 trial boards each carry one oscillator, with 20 original and 20 alternative. The existing program flags 14 alternative boards for missing side fillets. Track 14 flagged, six unflagged, and 20 original boards. The 70% figure is the call rate for those trial boards under that program. Confirm each apparent defect with relevant evidence before recording it as a failure. The result is not an estimate of the defect rate for the incoming lot. The camera may have missed the expected reflection on a shorter termination.

If the ordering option requires wettable flanks and unmounted parts differ from the drawing, preserve samples and the drawing and investigate the shipment with the supplier. If construction agrees and X-ray or cross sections show actual defects, trace paste, oven run, board position, and device lot and hold affected stock as needed. If the joints pass and the existing program cannot see the right features, approve an alternative inspection process and validate its detection against known good and bad examples. The two parts can have separate validated programs.

Nominal bottom pads can match while coplanarity or end chamfer differs. When one fillet disappears, check whether the condition follows the board position or the component geometry. Photograph and measure unused samples under comparable alignment against each drawing. A compliant smaller pad can sit outside a legacy inspection window. Use a confirmed marginal good joint and a known real open to test whether angle, focus, or illumination changes distinguish the two. Record the qualified equipment and process. If a contract manufacturer changes its stencil, the joint may change even when the incoming termination does not. Repeat the assembly comparison with retained components and the new board process before assigning the result to the supplier.

Make inspectability part of alternate approval

Have purchasing send the new parts to both incoming inspection and assembly engineering. Retain termination construction, drawing revision, assembly results, and actual rejection criteria. If a customer mandates optical verification of a side joint, specify that capability in the RFQ. Compare the physical evidence with the program's response before deciding whether to reject a lot, correct the assembly process, or change the inspection.