A 10 MHz oven-controlled crystal oscillator that looks clean on the bench may show two equally spaced narrow lines around the carrier after installation in a fan-cooled enclosure. The enclosure can pass its mechanical vibration test and the oscillator can meet the static frequency limit while the operating receiver still sees those spurs. Before ordering a low-g-sensitivity part, verify that mechanical vibration causes the lines, measure the response in the installed orientation, and compare the result with the equipment’s spur limit.
Read three quantities from the spectrum
Record the carrier frequency f0, the single-tone vibration frequency fv, and the level L of one first-order sideband relative to the carrier. Use a nearby three-axis accelerometer to measure the peak acceleration a at fv on the driven axis, expressed in g. Discrete lines are reported in dBc. Continuous noise density is reported in dBc/Hz. The acquisition and normalisation differ. Substituting a density reading from a discrete line in a phase-noise display can mistake the measurement bandwidth and processing for device performance.
For small sinusoidal FM, the peak frequency excursion is Δfpk = f0 × |Γaxis| × a and the modulation index is β = Δfpk/fv. The first-order sideband voltage is approximately β/2 times the carrier voltage, giving |Γaxis| ≈ (2fv/(a f0)) × 10L/20. Morley and Haskell’s measurement paper derives this relationship from frequency modulation and describes separate measurements on three axes. The equation here applies to an oscillator with an output. For a passive resonator, the external excitation and resonator network bandwidth affect the sideband reading. Use the equation for that measurement configuration.
Work through a 100 Hz vibration example
Assume the shaker produces nearly single-axis sinusoidal vibration at 100 Hz and 0.50 g peak at the oscillator mounting point. One sideband of the 10 MHz carrier reads −86 dBc and the other is similar. Follow-up tests support frequency modulation as the main mechanism. Substitution gives |Γaxis| ≈ 2 × 100/(0.50 × 10,000,000) × 10−86/20 ≈ 2.0 × 10−9/g, or about 2.0 ppb/g. The corresponding peak frequency excursion is about 0.010 Hz and the modulation index is roughly 0.0001, so the small-signal approximation holds. If 0.50 g peak were misread as 0.50 g RMS and converted to 0.707 g peak, the inferred sensitivity would be about 29% too small.
If the equipment requires a sideband below −92 dBc at this offset, with the same carrier, vibration frequency and acceleration, the equation gives an allowable sensitivity of about 1.0 ppb/g. This illustrative limit is tied to a specified vibration frequency, direction and amplitude. The equipment can also meet the limit by reducing the actual acceleration at the oscillator. If the system then multiplies the reference frequency by ten ideally and transfers the phase modulation to the output, the carrier-relative sideband rises by about 20 dB. A real phase-locked loop has a reference transfer function. Evaluate its closed-loop response at the relevant offset.
Three checks before sending a supplier the conclusion
- Turn off the shaker and save the baseline
- Record the stationary spectrum and then apply vibration. If a spur already existed and does not follow a change in the excitation frequency, check supply noise, the motor drive and external signals first. Symmetric sidebands are a starting point. Sinusoidal AM can also produce two evenly spaced lines. Where needed, use a phase measurement with verified AM rejection or compare the measured phase with a synchronous acceleration reference to establish the dominant mechanism.
- Change amplitude and repeat on the same axis
- Double the peak acceleration within the permitted limits of the oscillator, fixture and shaker. A small-signal FM sideband should rise by about 6 dB. If it deviates materially, check whether local acceleration actually doubled and inspect transverse motion, fixture resonance, cable movement and the analyser floor. A response that changes when the mounting points move cannot immediately be attributed to the oscillator. A NIST experiment on vibration-induced phase modulation demonstrated how to correlate three-axis acceleration with phase output to identify pathways in mounted hardware.
- Change axes and retain mounting coordinates
- Measure each of three mutually perpendicular axes defined on the unit. Keep the accelerometer orientation and mounting method in the record. Discrete sideband powers give component magnitudes. The component sign requires its phase relative to acceleration. Under the same linear conditions and common phase behaviour, combining the components by root sum of squares gives the vector magnitude as a static-style bound on its directional projection. When the equipment has simultaneous axes with different vibration phases, combine synchronous transfer measurements and the actual accelerations instead.
Use a separate criterion for random vibration
If the running fan also produces random vibration, evaluate the continuous spectrum separately from the narrow lines. For a single axis, suppose the one-sided acceleration power spectral density Sa at 100 Hz is 10−4 g²/Hz and the sensitivity still equals 2.0 ppb/g there. The estimated phase spectral density is (f0/fv)² × |Γaxis|² × Sa = 4.0 × 10−12 rad²/Hz. For small phase modulation, the linear single-sideband phase-noise ratio is half that one-sided phase spectral density, or about −117 dBc/Hz. This is the vibration contribution calculated for an illustrative environment. The measured equipment spectrum also contains its stationary electronic noise and other coupling pathways. Submit both the stationary and driven curves at the same offset. For simulated enclosure acceleration spectra, record the location and mounting configuration so the next production lot can reproduce the comparison.
In the equipment, start by measuring shaft speed. A fan turning at 3,000 rpm rotates at 50 Hz. If a line occurs 100 Hz from the carrier, use the tachometer to check whether it follows twice the rotation frequency and simultaneously inspect acceleration near the oscillator. Tracking speed is a clue. To attribute the spur to vibration transmitted into the board, also check which signal changes when the fan support or electrical supply path changes.
A manufacturer's 2g tip-over result can screen low-frequency directional sensitivity, but has its own thermal settling conditions and cannot capture a board or fixture resonance at a particular frequency. A qualification request can specify carrier, vibration frequency, axis, peak local acceleration, permitted sideband level per side, duration and temperature. Request records with and without vibration. For random vibration, request acceleration power spectral density and the continuous phase-noise trace under vibration. A sinusoidal point calculation cannot qualify an entire noise band. The result can guide a choice between a lower-sensitivity oscillator, a different orientation and less fan vibration transmitted into the board.