A recorder feeds the PCM1808 a 12.288 MHz system clock but cannot decode left and right channels on the data line. Review the system clock and serial clock directions separately. SCKI receives the system clock. The directions of BCK and LRCK depend on interface master/slave mode. If both processor and converter drive frame clock on the same net, a counter can still report an average close to the expected frequency.
Check both mode pins before power-up
TI lists the MD1 and MD0 logic combinations in the interface mode table and requires them to be set before power-up. When both are low, the converter receives the external bit clock and frame clock. When both are high, it operates in master mode with the system clock at 256 times the sample rate. With the 12.288 MHz example, master mode yields 48,000 frames per second and produces 64 bit clocks per frame on BCK. Match each resistor population option to the processor audio-port direction and intended sample rate.
During testing, capture LRCK, BCK, and the data pin together on a logic analyzer. Count the actual bit-clock cycles in one frame and verify the serial data format. In slave mode, check the allowed frame width in the data sheet, especially because the 48-bit-clock format applies only at specified system-clock ratios. Seeing the left and right channels alternate does not establish correct sample alignment at the receiver.
If the prototype has provision for series resistors, use an approved method to isolate the two ends with power off. Confirm which side drives before reconnecting and testing the complete path. With both pins set as inputs, there is no clock. If both are outputs, correct configuration before joint bring-up. Record measured directions and mode-pin levels at schematic sign-off so a later sample-rate change can be traced to the frame source or system reference.TI PCM1808 interface modes and clock pin descriptions