The original BOM says 12.000 and a supplier proposes a powered oscillator in place of a two-pin crystal. TI specifies a 12 MHz clock within ±500 ppm for PCM2902C USB and audio operation. The device includes a crystal oscillator circuit and permits an external clock on XTI, but TI does not recommend external clocking because there is no suitable signal to turn the source off. Factor system power during USB suspend into the selection.
Compare the clock circuit and complete system power together
For the crystal circuit, TI specifies a feedback resistor and two capacitors sized for the crystal load. For external clocking, leave XTO open as documented and confirm input and supply compatibility. A shared clock may remain necessary to other functions during suspend. Verify before assigning SSPND to external-clock shutdown. Have engineering identify who owns the project’s suspend-current requirement.
Exercise a full cycle under actual host control
Start a USB audio stream and verify input and output. Have the host suspend the bus, measure board current and external clock state, then resume and confirm streaming. Pausing playback in a desktop app does not necessarily suspend USB. Keep other subsystem states and measurement points consistent so speaker or amplifier supply changes are not attributed to the reference source.
Make the production choice using frequency accuracy, power consumption, and resume behavior together. If keeping the manufacturer's preferred crystal circuit, include the full load and electrical requirements in the request. If the design genuinely needs a shared external clock, attach verified suspend-control behavior and measured power consumption to the procurement approval. A common 12 MHz nominal frequency does not establish compatibility. TI PCM2902C Clock and Reset section