When sourcing a replacement for an older SaRonix part in the Pericom system, using a legacy table to translate every character can produce a complete-looking but unsupported new code. Page 2 of the F6/FX document retained by Diodes separates Part Ordering Information from Legacy Ordering Information. The current format has product family, frequency, and specification codes. The exact requirements are confirmed before assignment. The legacy table explains historical options.
Recover verifiable requirements from the original code
In the historical drawing, NKS denotes a four-pad seam-sealed package and NES a two-pad glass-sealed package. The old format also distinguishes calibration, stability, temperature, vibration mode, nominal frequency, load, and packaging. If only part of the label survives, record legible fields and leave the rest pending. A frequency match leaves the package distinction unresolved and cannot establish fit on the original PCB.
Some blank fields have a defined meaning. In the illustrated mode field, a blank differs from the fundamental-mode code. An empty load field also implies a particular resonance condition. Importing a legacy BOM into a new system can discard field boundaries, parentheses, or leading zeroes. Keep the original string and decoded requirements side by side. Have the supplier verify the mapping before requesting an assigned current order code.
Keep a photo of the original lands, the complete nominal frequency, and the approved specification. Ask whether the new assignment is equivalent to the original design, a discontinuation migration, or a proposed alternative. Historical manufacturer documentation supports code interpretation. Verify present availability, authorization, and lead time in a current written response.Diodes F6/FX page 2, Part Ordering and Legacy Ordering Information