Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Ordering a Pericom NX50SA for 50 MHz CMOS and 125 MHz LVDS modes

A communications board might need a 50 MHz active oscillator with a CMOS output in maintenance mode and a 125 MHz differential oscillator with LVDS in service. The engineer leaves one Pericom NX50SA on the drawing and asks purchasing for the family and two frequencies. The request still lacks information that determines whether the board can operate. Specify which state selects each frequency, which output logic applies in each state, whether the modes share the physical output, and how the receiver connects. If the system needs both clocks at the same time, two selectable states of one oscillator cannot supply them. Resolve the clock topology before ordering.

Ask for a complete configuration for both select states

The Pericom data sheet published by Diodes maps an FS low to state 1 and an FS high to state 2. The manufacturer allows requests for different output logic in the two states. The family supports CMOS, LVDS, and other interfaces. The ordering diagram reserves a specification code after NX50SA. A buyer can request 50 MHz CMOS for state 1 and 125 MHz LVDS for state 2, and ask the supplier to return the corresponding complete code and a configuration table. That combination is an RFQ example. The family sheet does not give it an orderable code. A document with just the family prefix can support feasibility review. Keep order approval open pending confirmation of the specific part. A dual-frequency product entry alone cannot establish that both output interfaces are configured.

Assign pins against the confirmed code. The family table shows pin 1 as frequency select or output enable and pin 2 as frequency select, output enable, or no connection. Pins 6 and 3 carry supply and ground. Pins 4 and 5 occupy the output positions. The order attachment should specify the actual functions of pins 1 and 2, the startup state, which pin drives the CMOS output, and what happens to the other pin in that state. Use a line for each state and review the schematic symbol at the same time. Combining a family overview with pin assignments from an old board built for a different suffix can turn an intended frequency toggle into an output-enable test.

Suppose the candidate has a nominal 3.3 V supply. The published range is 3.135 to 3.465 V. FS and OE require at least 0.7 times the supply for high and at most 0.3 times the supply for low. Across that full supply range, use the maximum supply to calculate a 2.4255 V high requirement and the minimum supply to calculate a 0.9405 V low limit. If the board controller guarantees only 2.2 V for a high, it falls 0.2255 V short even if one bench board switches to state 2. Resolve the control interface in design and use valid control levels on the incoming test fixture. Link the results so the board problem and the programmed state can be traced separately.

Test with both loads and keep both records

The NX50SA family table specifies a 15 pF output load for CMOS and 100 Ω with 5 pF for LVDS. The same oscilloscope can check the single-ended 50 MHz oscillator and differential 125 MHz oscillator in their respective states. Change the termination and probing to match. If both receivers are to remain hardwired close to the output, draw the load present in each state. Check the real assembly if the differential resistor remains connected in CMOS mode, or if an inactive input adds a clamp path or capacitive loading. Engineering can also design suitable isolation or separate clock sources. Two correct frequency readings on a scope cannot establish that both receivers get valid levels.

Allow for the two states in the power review. The family specifies maximum CMOS and LVDS-group currents of 60 and 70 mA respectively. Multiplying each by the 3.465 V supply maximum gives about 208 mW and 243 mW of oscillator input power for preliminary rail budgeting. These are calculated figures, not measured sample power, and they exclude any separate dissipation in downstream receivers or external termination. Request current limits for every state if the proposed item lacks them and note whether the board measurements included the receiver. Once each state settles on the fixture, record frequency, termination, waveform, and supply current. If the system has a switching requirement, test recovery between states separately, with the upper-level receiver held inactive as required by the project.

Confirm the default state even when one setting is used only for factory maintenance. On a verification board, select each state before a power cycle and then try switching with the supply on. Record the pre-power selection and the first stable output in the same table. Repeatedly flipping a switch on an already powered board can miss the interval in which a processor pin starts in high impedance. If a receiver can sample the clock immediately at startup, specify the default mode and how the receiver should behave during initialization. The test helps distinguish a firmware problem restoring the selected mode from an oscillator configuration that maps the two states in reverse.

Match the two waveforms to one ordered configuration

An approval can attach two steady-state records to one specimen. The first records FS low, the supply option, the 50 MHz single-ended waveform, and its load. The second records FS high, the 125 MHz differential waveform, and its termination. Verify that both came from the same complete code and identification record. Mark a waveform without its selection conditions as incomplete. If the supplier can confirm both frequencies but offers just one output standard, engineering can review that as a separate proposal before approval. Receiving and manufacturing can rely on the full code once the quotation, assembly drawing, and first-article records specify the same frequencies and output logic in both states. Keep the configuration in the service file so a technician can distinguish an incorrect selection level from a termination error.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.