Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

The Pericom PI6LC4840 needs 50 MHz at QA. Why does the BOM still call for a 25 MHz crystal?

An older network board marks 50 MHz beside QA0. A buyer looking along that net may ask for a 50 MHz active oscillator. Pericom distinguishes the two positions. X1 and X2 take a 25 MHz passive crystal, while the QA bank supplies a clock derived from the internal synthesizer. Whether 50 MHz appears and how many outputs are enabled depends on the mode pins and supplies. On partly populated variants, a fixture can also find the right frequency on a different live branch. Identify the component position and the output before updating the order.

Use the pin table to identify the installed part

The block diagram shows a SaRonix-eCera FL2500029 as the example 25 MHz crystal and a separate REF_Out buffer for the fundamental clock. QA supplies selectable 25 or 50 MHz single-ended outputs, QB supplies 125 MHz single-ended outputs and QC supplies 125 MHz differential outputs. An FL marking in a board photograph can help identify the reference position. Match it with the original part record, specification and traceable shipment paperwork. A few characters do not establish the orderable part or supply channel.

If the original circuit stays with a 25 MHz passive crystal, request its complete part number, load, ESR, temperature range, drive limit and terminal drawing. If a new design bypasses the synthesizer and sends a 50 MHz active oscillator straight to a receiver, give it a separate hardware approval covering supply, levels, load and the remaining clock domains. This version of the manufacturer data sheet identifies X1 and X2 as crystal oscillator pins. The frequency measured at QA is not a basis for changing the frequency applied at those pins. Any temporary reference injection also needs an approved circuit and method.

The crystal table gives 18 pF typical load, 50 Ω maximum ESR, 7 pF maximum shunt capacitance and a drive entry of 0.65 mW. The latter equals 650 µW and needs review against the table and actual application. Do not substitute a generic drive figure. For an 18 pF crystal the reference circuit shows two 27 pF capacitors and allows frequency adjustment for layout. Keep rated crystal load on the part record and installed capacitors on the assembly record. Combining these values can produce both a wrong order and an unrepeatable inspection.

Check which branches the mode actually enables

Read the operating table in Mode_2, Mode_1, Mode_0 order. With 100, QA0 carries 50 MHz and QA1 and QA2 are high impedance. With 110, QA0 and QA1 both carry 50 MHz while QA2 remains high impedance. These rows also enable different numbers of QC branches. The 111 row leaves all outputs in the table high impedance. Send the resistor stuffing with the correct board revision and verify the actual straps, rails and outputs on the first article so the one-output and two-output versions remain distinct.

Use period for a simple cross-check. At 25 MHz it is 40 ns, at 50 MHz it is 20 ns, and at 125 MHz it is 8 ns. If QA0 and REF_Out both show 40 ns, both observations indicate 25 MHz. Check the QA mode selection before attributing it to a wrong crystal. If QA0 shows 20 ns but QA1 has a static level from another circuit, inspect all three mode pins and the QA rail. Reset is another explanation for a stationary line. The manufacturer says master reset pulls the single-ended outputs low. Capture reset timing with the clocks.

Collect separate evidence for components and assembled boards

Pericom specifies 3.3 V ±5% for the core and relevant output supplies, or 3.135 to 3.465 V. Verify the actual QA and reference-buffer rails on first articles. Separate output supply pins mean a good REF_Out does not prove QA power is present. The total current line in the data sheet also uses unloaded outputs. Check real assembly current with the number of branches and receiver capacitances actually used. If the bench report simply says the 3.3 V supply is good, add the exact test points and readings.

Save baseline data from the same board with its qualified 25 MHz passive crystal. Capture cold startup, buffered reference and the active output banks. Keep the other components and straps constant when comparing an alternate. Use an approved buffered measurement point to avoid loading the crystal circuit. If the new part produces a stable reference but the failure appears only on one enabled QA branch, inspect its load, supply and soldering before rejecting the crystal. If reference and several branches disappear together, check crystal startup, master reset and core power on the same trace.

For a frequency check after replacement, use the expected ratio as a diagnostic. Suppose there is no other modulation and the synthesizer is stably locked at a fixed ratio. A 500 Hz high error at 25 MHz is 20 ppm, which becomes a 1,000 Hz high error at 50 MHz. Similar fractional errors point back toward reference frequency or loading. If only one branch has poor edges, inspect its power, load and termination. The ratio helps localize a fault and cannot replace a jitter limit.

The material release can record the crystal code, load and temperature while the board record identifies which QA outputs need 50 MHz and the straps used to select them. Treat a vendor's same-frequency active oscillator as a separate circuit proposal. For a crystal change, retain lot traceability, board revision, mode-pin settings and receiver waveforms. The next production run can then establish whether the wrong part was issued or the required branch was never enabled.

References