A loop configuration change improves integrated output jitter, but the receiver is sensitive to a specific modulation band. Apply controlled sinusoidal phase modulation to the reference, sweep modulation frequency, and measure the input and output edge movement. The transfer curve shows how the loop amplifies or rejects a particular disturbance. It also separates frequency multiplication from the timing variation measured in picoseconds.
The same 20 ps means different phase at two carriers
Phase and time amplitudes obey Δφ = 2πfΔt. A 20 ps peak modulation at 125 MHz is about 0.0157 rad. At 500 MHz the same 20 ps is about 0.0628 rad. The phase gain is four, about +12.0 dB, while the time-jitter gain is 0 dB. State whether the plot uses actual phase, phase gain normalized by the multiplication factor, or direct time ratios. The latter two are equivalent in the ideal conversion.
An output component of 25 ps for 20 ps input is 20 log₁₀(25/20), or about +1.94 dB. A higher-frequency result of 2 ps is −20 dB. Use the same amplitude convention for both ports. Peak-to-peak on one channel and RMS on the other would give the wrong ratio. Verify the actual input modulation at the board because buffering and termination can alter the applied signal.
Start with a few modulation points
Fix carrier and receiver amplitude and sweep below, near, and above the loop bandwidth. Confirm lock and record settings, dividers, multiplication factor, and temperature. Use suitable simultaneous acquisition or a phase instrument that resolves the modulation component. Record the timing reference used to evaluate phase on both channels. Recovery from the modulated input can cancel some common modulation in an output measurement, depending on the instrument architecture.
Capture sufficient complete modulation cycles at each point. At 50 Hz, twenty cycles need about 400 ms of continuous observation. A short interval can underestimate modulation if it lands on a flat portion. Keep enough timing bandwidth on both channels. A spectral sideband method needs a predominantly phase-modulated small-signal stimulus. Vary modulation amplitude to check that the measured response scales. If a large stimulus drives the loop out of lock, treat that as a tolerance test.
Evaluate the actual interference frequency
If the reference has a 20 ps modulation at 30 kHz and the output limit there is 10 ps, a measured +1.94 dB peak predicts 25 ps. Investigate loop settings or the source of the disturbance. A −20 dB ratio predicts 2 ps for that input. Device noise and supply spurs still contribute independently to total output jitter. Save a baseline with modulation off so the driven coherent line can be distinguished from the existing spectrum.
Log input and output amplitudes, modulation frequency, ratio, and lock state at each point. Low-frequency gain, high-frequency attenuation, and peak gain answer different requirements. Add measurements around the expected transition before drawing conclusions about a sensitive band from two widely spaced points.
When input and output are measured separately, verify the applied modulation independently. If the measurement path contains a divider, use the actual carrier at the measured point. Ideal division reduces phase amplitude and carrier frequency together, preserving the equivalent time modulation. With a sideband method, save carrier, offset, detection bandwidth, and fit quality so a nearby fixed spur is not mistaken for the modulation response.
Temperature, reference configuration, and supply mode can affect a loop. Start with modes used in production. If results must hold at temperature extremes, choose initial sweep points at room temperature and add resolution near the estimated peak at the corners. Archive the loop settings or register readback alongside the curve so a later firmware configuration can be compared.