The lock light is on. When is a VCXO-based loop ready for measurement?

Some instruments start acquisition as soon as firmware sees the lock pin go high after changing frequency. A short initial frequency offset warrants reviewing how the PLL declares lock. The detector may require only that phase-detector error be inside a window for several consecutive cycles, while the application needs output frequency to stay inside a tighter range. These tests can produce different ready times.

Put the lock indicator and actual output on the same time axis

ADI AN-873 describes digital lock detection on the ADF4xxx family. Its frequency-hop simulation shows that the digital flag may assert before frequency and phase finish settling. It also discusses circumstances in which loss-of-lock detection may not behave as expected with a narrow-pull-range VCXO. An old bench delay cannot simply be reused after changing reference, phase-detector frequency, or loop parameters.

Mark the frequency write, first lock-indicator assertion, and entry into the application's error band on one time axis. Define that band for the actual use, including any continuous hold time, and record excursions after the first entry. An overly long frequency-meter averaging window can hide settling. For segmented acquisition, align segments to the frequency-change command and state timing resolution. Check upward and downward hops separately, since tuning margin may differ by direction.

If the indicator consistently precedes application-level settling, add a verified post-lock delay or frequency check in firmware, and handle cases that never meet the conditions. Specify the maximum time from the change command to usable output under defined reference and load conditions in purchasing requirements. That preserves the application's constraint when evaluating replacements.ADI AN-873 digital lock detection and frequency settling examples