When selecting a temperature-compensated reference for a synthesizer, suppliers usually give a phase-noise curve for the reference oscillator itself. Acceptance concerns the multiplied output. An ideal multiplier scales phase variations in radians by the frequency multiplication ratio. Carrying the reference curve unchanged into the output budget omits that scaling.
Estimate the reference noise contribution first
At offset frequencies the PLL tracks well, a net reference-to-output ratio of 10 raises the ideal reference phase-noise contribution by 20 log₁₀(10), or 20 dB. For example, −140 dBc/Hz at an input offset corresponds to about −120 dBc/Hz of reference contribution at the same output offset. The detector, dividers, oscillator, and other internal sources also contribute. Keep the offset frequency fixed when making this conversion and verify the actual multiplication ratio.
Outside the loop bandwidth, transfer of reference-clock disturbances is suppressed and the output oscillator's own noise may dominate. Adding 20 dB uniformly to the entire input curve can lead to the wrong choice near the knee. Obtain the transfer curve for the actual settings from the loop model or the manufacturer's design tool, then compare noise sources by frequency range. When several independent power contributions apply, convert them to linear units before summing.
Compare two references with known differences while keeping the loop settings, output frequency, and instrument settings fixed. If close-in noise improves and far-out noise hardly changes, upgrading the reference further may do little for the far-out requirement. Define the offset band that controls system performance, then request the relevant limits or curve.ADI PLL fundamentals and reference-noise transfer