An old receiver has two similar metal cans in its IF section but only one crystal-filter BOM item. Raltron lists the 10M7A as a two-pole filter in one A-3 package, and the 10M7B as four poles in A-3×2. Two cans may form one filter rather than two independent filters. Reconstruct the complete stage before asking how the manufacturer supplies a set.
Check how the two cans are connected
Trace the IF path from input to output and identify the coupling elements, matching networks, and reference designators. Ask the supplier for the four-pole wiring diagram, physical parts per set, markings, and external components to provide. A-3×2 describes the package arrangement. Confirm whether pricing is per can or per set, and whether a matched pair is required for the specified response.
Apply the pole-count difference to performance and quantity
Both entries have a 10.7 MHz center and a stated passband of ±3.50 kHz, but attenuation at specified stopband offsets, passband ripple, insertion loss and required termination differ. Substituting two poles may still pass the signal but reduce adjacent-channel rejection. Sweep the whole filter under the original matching conditions and compare passband and stopband response.
List sets per unit, parts per set, and each mounting position on the order. Ask the supplier how many sets each package contains. If matched sets are required, issue and return parts as sets. When separate issuing is permitted, retain the pairing details so repair does not break up a qualified filter stage. Raltron 10M7 series pole count and package configuration