Rakon ROM7050PA at 10 MHz: check acquisition before ordering the low-g option

A mobile electronics board uses a standard 10 MHz Rakon ROM7050PA. With the enclosure secured on the bench, its receiver locks every time. A move to a vehicle bracket prompts engineering to specify the low-g-sensitivity option. Purchasing plans to add the option to the existing order. One specification deserves a fresh look. The frequency-calibration footnote gives a different limit for the low-g option. A receiver designed around the original initial error can encounter an acquisition failure while the equipment is stationary.

The two specifications answer different questions

The ROM7050PA data sheet covers calibration under frequency stability. Standard calibration accuracy is ±0.2 ppm at 25°C ±2°C. A footnote gives ±0.5 ppm when the low-g-sensitivity option is offered. The vibration specification gives the fractional frequency change per unit acceleration. Its optional vector g-sensitivity is 0.7 ppb/g typical and 1 ppb/g maximum. Calibration describes the possible frequency offset under the specified stationary conditions. The acceleration figure describes the frequency's response to acceleration. Put each value on its own line in the procurement record. Retain the footnote and data-sheet revision so that the supplier's response can be checked against the design.

At 10 MHz, 1 ppm is 10 Hz. Factory calibration accuracy of ±0.2 ppm is ±2 Hz around nominal. Accuracy of ±0.5 ppm is ±5 Hz. Suppose the acceleration component projected along the direction of maximum sensitivity is 0.5g at a given moment. A maximum sensitivity of 1 ppb/g gives a frequency change with a magnitude of 0.5 ppb, or 0.005 Hz at 10 MHz. This illustration applies to the stipulated acceleration component. Actual vibration qualification still needs the mechanical orientation and vibration profile. The conversion puts a few hertz of initial error and a few thousandths of a hertz in the illustrative acceleration case into perspective.

Verify acquisition and then evaluate the locked clock

Suppose the board's receiver has a guaranteed acquisition window of 10 MHz ±3 Hz. Considering initial calibration by itself, the standard option with ±2 Hz leaves 1 Hz on either side. The low-g option can be 5 Hz off nominal, which extends 2 Hz beyond each side of that window. A sample at +0.6 Hz that starts correctly establishes what that sample did under those conditions. A succeeding reel can contain compliant parts closer to the ±5 Hz endpoints.

Also check the separate reflow-shift specification. The data sheet lists ±0.5 ppm and specifies conditions that include a one-hour recovery at +25°C. A conservative addition of the two absolute limits, provided both apply to the agreed configuration, gives 2 plus 5 Hz, or 7 Hz, for standard factory calibration. The low-g option gives 5 plus 5 Hz, or 10 Hz. The sum covers initial calibration and reflow shift. The system budget still needs to address operating temperature, warm-up, supply, aging and the receiver's own errors under the intended conditions. If the project needs to isolate reflow's contribution, record paired readings from each device before and after the process.

Document the option and the receiver action

Ask the supplier to acknowledge the complete ordering configuration, the low-g selection, its calibration limit and the maximum g-sensitivity. If the supplier offers a selected or screened reel, establish who guarantees the limits, which test conditions apply, whether the limits extend to production orders and what documentation will accompany them. A tighter calibration requirement calls for a written commitment covering the configuration or a receiver design that accommodates the published limits. A favorable reading on a selected sample can help diagnose a problem.

Use two independent bench exercises. First, substitute a checked signal source for the 10 MHz OCXO. With equivalent input levels and power conditions, step the frequency offset and restart the receiver at each point. Record whether it acquires within the required time. Sweep both directions. Acquisition on a cold start and the range over which a receiver stays locked after acquisition are different measurements. Second, assemble boards with parts from the agreed configuration. Record when power is applied, when frequency can be measured and when the receiver reports lock. Retest under the stipulated stationary and vibration conditions. Save the orientation, acceleration conditions, board identity and part number. A failure under vibration leads to a check of mechanical transmission and dynamic response. A failure while stationary leads first to the starting frequency and acquisition window.

Keep the measurement timebase allowance with the frequency record. If the lab allocates ±0.2 Hz to the measurement chain, a reading of +2.9 Hz can extend to +3.1 Hz and cross the stipulated acquisition boundary. Treat that result as indeterminate, then use a better reference, reduce uncertainty or widen acquisition and retest. Sample the applicable conditions after assembly. A reading taken just after power-up belongs in the start-up trace. Compare a stationary result against the data-sheet limit after the specified temperature and stabilization conditions are met.

Production approval depends on covering the guaranteed initial limits of the ordered option in the cold-start design. When the system has that margin, keep the low-g option and its calibration footnote together in the material specification. With a ±3 Hz acquisition window, samples can still support engineering evaluation while the team widens acquisition, establishes a controlled calibration process or secures a tighter written calibration limit. Base production approval on a verified solution and test records for the same ordering configuration.

References