An old receiver calls for a “10.7 MHz crystal component, 25 kHz channel,” and the candidate is Raltron's 10M15A. The manufacturer lists it as a monolithic crystal filter with a 10700 kHz center frequency, 25 kHz channel spacing, and a passband specified at ±7.5 kHz from center at 3 dB. These are three distinct figures. The two sides together give a roughly 15 kHz passband. The 25 kHz spacing is not its 3 dB bandwidth, and a single resonator cannot replace this filter.
Use the table to check adjacent-channel rejection and wanted-signal bandwidth
Ask receiver engineering for required modulation bandwidth, allowed passband ripple, insertion loss, and attenuation at specified offsets. The same manufacturer row also gives stopband points and termination impedance. A narrower filter at the same center frequency can attenuate wanted content, while a wide enough passband can still have inadequate stopband rejection. Keep the original column headings and units in the comparison.
Measure samples with the specified termination
Check both the resistive and shunt-capacitive terms of the specified impedance and document any adapter or matching network. Direct connection between two 50 Ω instruments may not reproduce the datasheet loss and ripple. Verify the fixture first, then compare the accepted and candidate parts with identical settings. Retain passband, adjacent-channel, and stopband traces.
The repair list can include the old package, pin layout, and a drawing of the board matching components. Record the device type, center frequency, and passband requirements separately. When the next request arrives verbally as “10.7 MHz,” use those fields to identify the required IF filter before ordering. Raltron monolithic crystal filter selection table