Why two 2 g RMS random vibration tests can produce different clock behavior

A single acceleration total omits the excitation spectrum. RMS acceleration comes from integrating acceleration power spectral density over frequency. Two profiles can have equal area but deliver different energy near an assembly resonance. Retain the table control spectrum, local response, and clock-event timing. IEC 60068-2-64 describes broadband random vibration methods. Apply the full profile, duration, axis, and operating state of the relevant plan.

Put the same area in two places

For a one-sided example, profile A is flat at 0.020 g²/Hz from 20 to 220 Hz. Its area is 4 g², or 2 g RMS. Profile B is flat at 0.005 g²/Hz from 20 to 820 Hz and also gives 4 g². Between 200 and 210 Hz, however, A contains 0.20 g² while B contains 0.05 g². The integrated mean square differs by four. A report stating only 2 g cannot reconstruct this difference. Verify density units. An amplitude spectral density in g/√Hz needs squaring for an area calculation.

If the PCB's acceleration transfer magnitude is approximately three around 205 Hz across that example band, the local mean-square contribution there is nine times the input. The examples give about 1.80 g² and 0.45 g² respectively. This applies only in that band. The overall 2 g RMS does not all get multiplied by three. Board flex and connector movement can also affect timing. Check local response near the event before using a total to predict clock behavior.

Align control, response, and electrical events

Under the approved operating conditions, monitor the control spectrum and measure a local response where allowed. Verify sensor axes, sampling, usable bandwidth, and antialias filtering. Minimize added sensor and cable mass on small assemblies. Identify the channels included in feedback and those used for observation. Save actual and target spectra with frequency bins and integration bands, including any control limitation.

Record output errors, receiver unlock, retries, and recovery. Use a common trigger or time markers to align with acceleration. Inspect a sufficiently resolved short-time spectrum near each event instead of averaging the entire run together. Coincidence with a response peak gives a lead. Confirm by repeated tests and independent supply monitoring. A permitted lower-level, narrow-band diagnostic can further investigate a structural mode. Keep it labeled separately from the formal verification.

Preserve what a later comparison needs

If a report says only “2 g RMS, normal,” recover the control profile, actual readings, mounting, and functional monitoring. If the requirement is continuity under profile A and the receiver unlocks twice near a large local response at 205 Hz, retain time and configuration details. A pass under profile B describes a different distribution even though the RMS value is equal.

Confirm RMS was calculated over the required frequency band and active intervals. Ramp-up and setup periods can make an overall statistic differ from the prescribed steady-condition PSD. Preserve target and actual control spectra, local spectra, integration range, duration, and working state. For comparisons, align frequency resolution and mechanical conditions and use the critical bands and actual clock performance.

Keep axes distinct when testing them in sequence. Horizontal and vertical stiffness can differ, producing a narrow response peak in just one axis. Averaging axes can hide the orientation most disruptive to the clock. If mounting changes, compare that orientation under equivalent excitation.

If exports lack PSD units, determine whether entries are per-bin power, density per hertz, or amplitude. Integrating evenly spaced PSD bins requires their bandwidth before summation and square root. Use actual bin widths when joining bands. Incorporate the calculation into the saved analysis so the area can be reproduced.

References