When a dual 10 MHz reference system's primary comes back, should it switch back automatically?

Two 10 MHz TCXOs provide primary and backup references. The backup took over when the primary disappeared. The more difficult decision is whether to switch back immediately once the primary returns. If it is intermittent, an early return can turn one fault into repeated switching. If the system must track the designated primary, remaining on the backup indefinitely violates operating requirements. Capture the choice in the clock controller policy and acceptance cases.

Keep “qualified” and “selected” in separate columns

For example, the AD9545 selects references by priority and supports revertive and nonrevertive modes. Define failure criteria, how long to observe recovery, and who initiates a return when the backup remains valid. Revertive operation fits deployments with a clear preferred source that can tolerate another transition on recovery. Nonrevertive operation suits systems that should retain the current source until a designated maintenance period. Record the operating mode and reference qualification criteria. Assigning a higher priority to input A alone does not explain live behavior.

With the backup valid, disconnect the primary, wait until the backup is active, and then restore the primary. Record when the primary qualifies, when the active reference changes, and when output phase begins its transition. Then test a brief recovery followed by another loss to see whether the controller switches repeatedly. Two sources at the same nominal frequency can have different initial phases. Check whether the downstream system tolerates the resulting phase movement.

If the contract says only “no interruption,” specify minimum output pulse width, maximum allowable phase deviation, and recovery time. The reference status register identifies the selected source. Continuous output captures show what downstream equipment experienced. Put normal return and intermittent recovery results on the same decision sheet so on-site operators have a clear recovery procedure.ADI AD9545 reference switching modes and priority documentation