Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Which output should receiving verify for a Renesas XPC736 156.25 MHz differential oscillator?

A buyer finds the Renesas XPC736156.250000I. Its manufacturer detail page lists CML, LVDS, LVPECL, and HCSL in the output field. The offer says only XP, 3.3 V, 156.25 MHz, and eight pins. A qualified LVPECL board might appear able to use this item. The manufacturer's exact-code addendum identifies XPC736156.250000I as CML. Confusing XPC and XPP can leave the measured frequency unchanged while altering the interface required by the board. Attach the complete order code and its output configuration to the request.

Resolve the catalog list using the exact-code addendum

The XP family ordering diagram uses the character after XP to encode the output. C indicates CML and P indicates LVPECL. The XPC736156.250000I and XPP736156.250000I addenda both specify 156.250000 MHz, a 3.3 V supply, ±25 ppm stability, a 7.0 × 5.0 mm body, enable on pin 1, and −40 to +85 °C operation. The output standards differ. The online list can help locate the family. File each addendum under its own part for approval. When a supplier proposes a third code at the same frequency, request its specific manufacturer document before accepting the interface.

In both addenda, pins 4 and 5 are complementary outputs and pin 6 is the supply. The documents identify serial pins 7 and 8 as unused for fixed XO mode. The common positions still require a board drawing appropriate to the output. Trace the termination rail, receiver bias, and any AC coupling. The family sheet's CML example has two 50 Ω resistors pulled up to the applicable supply near the receiver. LVPECL has separate termination drawings. Check the receiver's supported input and supply sequencing before applying either example. Procurement can record the applicable board revision after engineering verifies the connection.

A correct frequency still leaves the interface unresolved

The common ±25 ppm limit gives a one-sided deviation of 3,906.25 Hz when applied to 156,250,000 Hz. The calculated endpoints are 156,246,093.75 Hz and 156,253,906.25 Hz. Suppose a device in valid test conditions reads 156,250,600 Hz. Its positive 600 Hz deviation is 3.84 ppm. That reading falls inside the numerical window for either item and cannot identify the output standard. After measuring frequency on a valid fixture, check the actual DC operating points and differential waveform against the intended receiver. If the fixture is shared, verify its termination selection before taking a trace. Assign different test configurations to the two load diagrams so a generic differential label cannot be mistaken for a full setup record.

If the wrong termination was fitted during a fault investigation, retain observations before and after correction. A newly received 156.25 MHz differential oscillator might show the right frequency on the warehouse CML fixture while causing an unreliable receiver in service. Check whether the LVPECL work order received CML material. If the complete code is correct, examine the board measurement and receiver data sheet. Use the factory label and a retained unassembled specimen to restore the identity trail before assigning the cause. A repeatedly reworked sample is weak evidence when both the item code and fixture have changed.

To qualify the fixture, photograph the adapter with each termination module in place. Identify the source and receiver ends and measure the actual termination rail. Leaving the fixture resistors in place while enabling a 50 Ω scope input on each leg changes the load. Use a differential probe or other validated connection and retain the instrument settings in the test procedure. Record whether each receiver enables internal termination. A receiver held in reset may present a different input configuration. Tie the recorded waveform to the receiver state used in the acceptance conditions.

Include the output in incoming and substitution instructions

Preserve labels and lot records even when the top shows the abbreviated frequency. For this package size, the XP marking section describes a truncated part number on the first line and shortened frequency and lot information elsewhere. Compare the characters with the reel label and retain a first-article image for future inspection. If the commercial document says XPC while the carton or reel says XPP, retain images and the data sheets and hold production issue. A replacement label must preserve the mapping to the original part and lot. Changing paperwork by itself does not establish that identity.

Use the two codes to audit materials data. An importer that treats the entire web output list as valid for each part can make both appear in an LVPECL stock filter. Use the single value from the exact-code addendum for ordering and retain the web page as a lookup. A customer-facing family alias can still help users search for the item without enabling automatic substitution. If engineering changes the receiver, retrieve the permitted output and fixture number from the revised board record. Before sending a new quote request, trace every output field to the applicable manufacturer document and recorded confirmation.

An RFQ can specify the required 156.25 MHz differential oscillator, the exact output standard, approved manufacturer code, and board revision. Attach the applicable termination. An alternative output belongs in substitution review for a possible PCB or receiver configuration change. It cannot go straight into the existing work order. Shipment records can identify the code, frequency result, and actual termination used. Compare the incoming lot to an approved reference so both receiving and engineering can confirm the interface as well as frequency.