Where did 20 nA of extra RTC backup current come from?

Backup current on an RTC board can increase by tens of nanoamperes because of test cable insulation, relays, or contamination. Define the measurement plane and compare a biased blank, a check load, and the working board. Use the instrument's driven guard according to its manual. Reduce known fixture leakage before applying any correction to a product result.

A weak leakage path can account for 20 nA

At 2.8 V, an equivalent 140 MΩ path to return carries 20 nA. At 1 GΩ it still carries 2.8 nA. An 85 nA board plus 20 nA of fixture leakage might read 105 nA, enough to flip a 100 nA decision. A blank needs comparable node potentials to expose that effect. An unpowered fixture showing zero checks a different condition.

A triaxial inner shield can be driven near a sensitive node's potential, reducing the voltage across leakage paths. If the illustrative 140 MΩ path sees only 20 mV, it contributes about 0.14 nA. That is one path only. Follow the instrument wiring for outer shield, guard, return, ratings, and load. Connecting a guard terminal to return can defeat its intended behavior.

Run three checks under comparable bias

First use a biased blank reproducing cable, relay, shield, and test-node conditions. Record settled leakage and drift at 2.8 V. Next use a verified high-value resistor or low-current reference to check range, settling, and analysis. Finally install the RTC board, remove main power, and confirm real backup operation. Pullups, debug connections, or communications can backfeed it. State whether current is measured at the dedicated pin, the board battery port, or the fixture inlet.

A large initial reading that falls slowly may be cable charging or a backup capacitor. Use matching connection history and waiting intervals for blank and board. Probe movement can produce triboelectric spikes. Record temperature and humidity, especially after chamber opening or fixture cleaning. A blank measured once cannot automatically correct later tests under changed conditions.

Qualify the bench and preserve the real board load

If biased blanks repeatedly draw about 20 nA and a validated guard reduces that to a few nanoamperes, improve the setup first. Repeat the device measurement with its uncertainty. If the effect follows the actual board only, investigate manufacturing cleanliness and insulation using suitable test coupons. Real board leakage draws battery charge. An external guard that bypasses product current cannot produce the assembled-board total.

For a 100 nA board limit, keep the stable interval, bias, plane, backup mode, guard wiring, and blank data. Save repeated mount and settling traces from marginal units. Verify clock or calendar operation without a diagnostic connection that changes the backup state. This supports both current acceptance and verification that the product was actually asleep.

At several permissible battery voltages, compare settled current after each step. Approximately proportional blank current supports a resistive leakage path. A jump of several nanoamperes at a range change warrants checking instrument bias and range behavior. Qualify each relay path with a biased blank because channels need not share one correction.

Define when a reading is stable before optimizing production time. If current still falls 4 nA per second in the final 3 s, extend observation and verify settling rather than averaging three points into a lower value. Recording the median and slope alongside the decision helps requalify replacement fixtures and cables.

References