Equipment stops after moving from cold storage into warm humid air and recovers after drying. A sound metal case on the external 32.768 kHz crystal does not rule out the failure. Analog Devices notes that low-power oscillator nodes have high impedance, so leakage due to nearby moisture can stop oscillation. The internal seal and leakage between terminals across the PCB are different issues.
Preserve the wet-state evidence, then run a dry-state comparison
Within the permitted environmental conditions, log temperature, humidity and board state around the fault. Start with repeated calendar reads or a documented buffered output to establish whether counting stopped. A probe can disturb high-impedance nodes. Hot-air drying before the first observation removes evidence about the wet state. Follow the equipment's service and power-up requirements for actual moisture exposure.
Compare a clean control and the suspect board under controlled conditions with the same crystal, supply, temperature profile and measurement time. Check whether it recovers after drying and recurs on the same board. Photograph pins and surrounding board before swapping crystals on separate samples. Desoldering heats and can clean the area, temporarily removing evidence.
If the high-impedance area is moisture-sensitive, review cleaning, drying, board protection and enclosure condensation control with production. Verify material compatibility with the crystal package. Specify the actual environment and protection rather than relying on a crystal substitution. Retain wet, dry and replication results for the manufacturer's failure analysis decision.Analog Devices: RTC crystal and layout guidance