Two products share an RV-3028-C7. One uses a primary battery, and the other is intended to use a supercapacitor. The manual shows a trickle-charging branch from VDD to VBACKUP, disabled by default. Configuration can enable it and select a series current-limiting resistor. If the purchase order says only that the backup interface is the same, assembly may pick rechargeable and nonrechargeable devices for the same job. Set the storage device and configuration in engineering first, then consider consolidating purchasing.
Match the battery model to the firmware configuration
With a primary battery, hardware and software must work together to prevent charging. Check other components for reverse-current paths as well. For a supercapacitor, verify rated voltage, permitted charging conditions, leakage, and required hold-up time. The RV-3028-C7 offers 3, 5, 9, and 15 kΩ resistor settings. Select one based on supply voltage, diode drop, and charging time. The lowest resistance is not automatically suitable, and a typical diode drop in the manufacturer's data is not a fixed value across temperature.
Verify two easily confused scenarios
First restore power after a prolonged outage and measure backup-device voltage and branch current. Then disconnect main power and verify time retention. Record whether the capacitor was fully charged before power-up and whether charging stays enabled after a cold start. Long retention with a precharged lab sample does not establish the same performance for an out-of-box unit disconnected immediately.
Put the backup-device order code, hardware revision, and configuration check value together in the assembly documents. Confirm voltage and configuration again after changing capacitor or battery. The RTC can be common while backup-source approval remains specific to each version. Micro Crystal RV-3028-C7 manual, Section 4.3