After removing main power and retaining backup, the host gets no reply from the RTC. Check whether the interface is supported in that state. The evaluation-board documentation says that SCL is disabled in VBACKUP operation and SDA is disabled and high impedance. A failed bus access alone does not establish that timekeeping stopped.
Write a known valid time with main power present, read it back, and log an independent reference time. Remove main power and verify backup voltage at the specified pin. Wait long enough for a conclusive comparison. Restore main power, wait until supply and interface conditions are valid, then read time and compare the increment with actual elapsed time. The board’s backup capacitor has finite capacity and leakage, so verify available hold-up before a long test.
The evaluation board pulls SCL and SDA up to VDD. A host with separately powered pull-ups can alter board power during an outage. Measure both main and backup pins and document bus cabling and instrument connections before removing power.
Report the main-powered, backup, and restored intervals separately. Compare the recovered calendar change with elapsed reference time. If it agrees, examine the host’s access expectations during backup. If time actually stopped, check the backup path, minimum voltage, and IC status. If the product requires reads without main power, verify that its architecture supports that access.Micro Crystal RV-3028-C7 evaluation-board pin table and backup-mode description