Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

Why does an RV-3028-C7 still generate a clock on an event with ordinary CLKOUT disabled?

A low-power system wants to leave its 32 kHz output off until a downstream device must wake. On the RV-3028-C7, ordinary CLKOUT and interrupt-event-driven output are separate paths. The evaluation board guide says both can be enabled at once. Clearing CLKOE alone does not guarantee no waveform.

Test a quiet interval and one defined event. Read CLKOE, CLKIE, the event mask, and relevant flags. Decode FD to find the selected output. Capture the event input, INT, and CLKOUT at the test points. If a square wave appears only after the event with ordinary output off, check the event-driven path first. Use FD to identify its frequency rather than assuming any toggling is 32.768 kHz.

The manual distinguishes blocking future events from clearing the already-set CLKF flag. Save the original status, handle the flag as instructed, and verify the current output stops. Then generate a new event to see whether it can start output again. These tests distinguish a latched prior event from subsequent retriggering.

If an event clock must wake a peripheral, retain the feature and measure its start time and duration. If the pin must remain quiet during every event, test both paths. The register definitions here apply to the RV-3028-C7. Save register states and waveform timing before and after the trigger.Micro Crystal RV-3028-C7 evaluation-board pin functions