Purchasing requires “calibratable timekeeping and a calibrated 32.768 kHz output.” The RV-3028-C7 has offset compensation and a clock output, but the internal signal paths matter. The manual says the 32.768 kHz output comes directly from the crystal oscillator without digital offset compensation. The 8192 Hz, 1024 Hz, 64 Hz, 32 Hz, and 1 Hz divided outputs do use compensation. Calibrating the calendar alone cannot meet an off-board requirement for a corrected reference at the original frequency.
Identify the clock's purpose at both ends of the connection
Ask whether the customer is calibrating the seconds display or needs a calibrated reference for off-board equipment. Record the downstream frequency requirement, short-term continuity, and long-term average deviation. If 1 Hz can be used for long-term verification, check whether the receiver can compare pulses. If an external counter must be driven at the original frequency, find a suitably specified source or correct it downstream. Digital calibration that improves long-term timekeeping does not scale every interval between consecutive edges equally.
Compare two output settings
At a stable temperature with the same reference, save the initial compensation setting. Measure the direct frequency, then a divided output compensated according to the manual. Change the setting and repeat, allowing enough observation time for the lower frequency. Record output selection, measurement window, and calibration value. If the equipment is only suited to high-frequency readings, track accumulated phase difference between one-second pulses. A short-window reading is not a long-term error measurement.
List requirements separately for the calendar, compensated divided output, and raw clock. If a manufacturer guarantee is missing, the purchasing review can then determine whether to change the interface or the requirement. RV-3028-C7 manual, Section 4.4: clock output