The customer wants to investigate temperature excursions during shipping. The supplier recommends the digitally temperature-compensated RV-3032-C7. Its manual specifies high and low thresholds, event counts, timestamps, and enable states at factory shipment and after reset. For one threshold-crossing timestamp, these functions are worth evaluating. A numerical reading every minute requires its own sampling and storage budget. One timestamp and count cannot reconstruct the whole temperature profile.
Sketch the report the customer needs first
Attach an example of the required record to the sample request: first excursion, most recent excursion, event count, or timestamped temperature at every sample. Check whether the documented first/latest selection, counting, and clearing meet the requirement. Verify register reset defaults and factory EEPROM settings separately, including whether the relevant functions are enabled on a new part. If monitoring begins at packing, define the order for time setting, status clearing, and enabling capture.
Use two excursions in the sample test to verify event retention
Under controlled conditions, cross the threshold once, return to the normal range, and trigger a second event. After the two triggers, read the timestamp, count, and status flags to see whether the first or most recent event is retained. Then use the product's actual power arrangement to verify which functions remain active with the host powered down and whether the host can retrieve the record after recovery. Include the temperature sampling interval and actual thermal response in the test because they affect whether short events are captured.
State what event evidence the proposed part can provide. If the customer needs the full profile, quote the controller, nonvolatile storage, and battery budget separately. If one excursion timestamp suffices, approve against that narrower requirement without paying for continuous recording. Micro Crystal RV-3032-C7 event and timestamp documentation