The RX8900CE is a temperature-compensated RTC with a readable temperature register. A project considering removal of the ambient sensor needs to know what that register measures, how often it updates, and what accuracy the application requires. Epson says temperature data updates with compensation operation and gives the conversion from raw register value to Celsius. A readable temperature does not by itself represent the location measured by the ambient sensor.
Confirm data format before evaluating accuracy
The manufacturer converts the raw byte using (2 × value − 187.19) ÷ 3.218. A raw value of 134 gives about 25.1 °C. This demonstrates decoding, not accuracy. Have software confirm whether a read gives a new sample or the previous compensation result. For a rapid rise, check update interval and package thermal response. Faster bus reads may not produce more independent temperature samples.
Bring the actual measurement locations into the trial
Under steady temperature and rapid changes, compare RTC readings with a reference probe near the RTC and with the actual environmental point of interest. A nearby power device can make the RTC hotter than the air outside the enclosure. Match the production enclosure, airflow, and dissipation as closely as possible, and timestamp the readings. If the manufacturer does not guarantee the needed accuracy or measurement location, base removal on system validation.
Purchasing can retain an optional footprint for the separate sensor. If the RTC temperature later supports fault diagnosis, it can be limited to trend monitoring. Use formal specifications and verification data before assigning it an absolute temperature guarantee to customers. Epson RX8900CE temperature register documentation