Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

All 30 oscillator samples cold-started. Does that establish a failure rate below 1%?

All 30 samples started at the specified low temperature, so the observed failure proportion was zero. To draw conclusions about the entire production process, account for sample size, sampling method, and test opportunities per sample. Testing only the board that starts most readily or resetting one device 30 times does not represent 30 independent random samples.

Use zero observed failures to determine how much risk the test can exclude

In a simplified model with independent random samples and pass/fail outcomes, if the true failure probability is p, the chance of all n samples passing is (1−p)ⁿ. With zero failures in 30 samples, the exact one-sided 95% upper confidence bound is about 9.5%. That does not estimate the actual failure rate at 9.5%. It shows which range the observations cannot rule out at that confidence level. Under the same assumptions, a zero-failure result requires at least 299 independent samples to push the upper bound below 1%.

If chamber space is limited, test in groups and record the lot, chamber positions, and assignment to boards. Many samples from one lot do not replace cross-lot verification when furnace or wafer lots may differ. Define off time, thermal stabilization, and the startup success criterion so a larger sample does not combine inconsistent tests.

Report the number tested, failures observed, and sampling conditions separately. List the confidence limit as a statistical inference. If the customer uses a sampling plan with a defined acceptance number, apply that plan to the lot. This population estimate is not an acceptance sampling table. Retain traceability to each sample and its startup result.NIST methods for binomial proportion confidence intervals

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.