Purchasing wants two boards to share a 22.1184 MHz crystal, one using an SC16IS752 UART bridge. NXP documents a selectable divide-by-four prescaler in MCR as well as the regular integer divisor. With the usual 16× baud clock, 22.1184 MHz and a prescaler of one require a divisor of twelve for 115200 baud. With a prescaler of four, the same baud rate needs a divisor of three. Copying twelve to the second board can make the UART four times slower.
Recover the settings from hardware and firmware
Confirm the actual reference, each UART configuration, the active prescaler, and the divisor register values. Some drivers store the oscillator frequency in a board or device description and set the prescaler separately at initialization. For a shared crystal, verify that every required baud rate has a permitted integer divisor. A single supported high rate does not guarantee all legacy rates. Check allowed clock limits and the conditions of the board oscillator circuit.
Measure the bit period
Transmit a known byte repeatedly and measure the start and subsequent data-bit widths. Repeat under factory and production firmware. A terminal can show readable text despite an incorrect setting if it tolerates errors or detects baud rate automatically. Keep a table of each port's prescaler, divisor, and measured bit period so maintenance can catch a missing initialization setting.
If sharing the crystal prevents some baud rates from meeting tolerance, identify the affected rates to engineering before keeping two parts or changing the configuration. Cite the matching driver parameter version on the production order. NXP SC16IS752 baud-rate generator