Two tools can compute different duty cycles from the same trace. Start by checking the actual middle reference voltage. A nominal 50% reference first depends on the voltages identified as 0% and 100%. An instrument can use the minimum and maximum samples or estimate the two levels where the waveform spends the most time. Overshoot and undershoot change the resulting crossing level. Slow, unequal edges can turn a small voltage difference into a measurable timing difference.
A different midpoint shortens the measured high interval
Take a 40 MHz clock with a 25 ns period. Its settled levels are 0.2 and 2.2 V. The half-swing threshold is 1.2 V. A 12.5 ns high interval there gives 50% duty. If the same trace overshoots to 2.8 V and undershoots to −0.2 V, its min-max midpoint is 1.3 V. With local rising and falling slews of 0.5 and −0.25 V/ns, adding 0.1 V delays the rise crossing by 0.2 ns and advances the fall by 0.4 ns. The new width is 11.9 ns, or 47.6%, on the unchanged trace.
The example uses local linear slopes. If a trace crosses repeatedly due to ringing, software may select the first crossing or apply another qualification algorithm. When accepting a signal at a receiver threshold, record the absolute threshold and hysteresis. If the datasheet uses a percentage reference, apply its definition or the agreed base and top method. An average duty number alone does not establish minimum high and low intervals.
Recompute both ways using one raw acquisition
Confirm both tools analyze the same trace and valid period range. Plot their actual top, base, and midpoint values and inspect the associated crossings. Exclude power-up and idle intervals from a steady-state gate. A histogram may struggle when the waveform spends little time on one plateau. A separate estimate of stable levels from multiple periods allows both tools to use the same absolute crossing voltage. Agree on interpolation as well.
Compute minimum high and low widths per cycle alongside average duty. Averaging per-cycle ratios can differ from dividing total high time by total cycle time. For 20 and 30 ns cycles with high times of 10 and 12 ns, the per-cycle ratios are 50% and 40%, with a mean of 45%. The pooled ratio is 22/50 = 44%. Preserve individual results if the limit applies to each cycle.
Use the receiver's threshold for receiver acceptance
Suppose a receiver recognizes transitions at 1.3 V and requires at least 12.0 ns high. The illustrative 11.9 ns is marginal and needs the applicable decision rule, receiver threshold range, and measurement uncertainty. Consider edge slope, bandwidth, and interpolation. A manufacturer's half-swing requirement uses the 12.5 ns result at 1.2 V under the stated definition. Averaging those different measurements obscures what each means.
Document acquisition mode, bandwidth, gate, base and top algorithms, absolute threshold, and treatment of varying periods. For histogram calculations, platform stability can help reveal enable or load changes. Check both tools at the same threshold with a pulse of verified height and width. A clean verification pulse checks ordinary readings. Overshooting clock traces still require matching level-estimation rules.
Plateau levels can drift across a long record as load changes, AC coupling shifts the baseline, or a buffer heats. Plot high and low levels against time, then compute fixed-threshold and local half-swing widths over identical periods. Local half-swing shows relative-width changes, while the fixed threshold shows cycles that could lose usable high time at the receiver. Matching timelines help correlate control actions and supply ripple.
If the board has multiple outputs, verify both tools on a known stable output using the same level definition and gate. If earlier records lack raw waveforms or threshold definitions, do not apply the illustrative 2.4 percentage-point difference as a blanket correction. Repeating both methods on a check sample can bound the impact of the change.