A battery logger switches off part of its power tree during sleep. There is no 32.768 kHz waveform at the SG-3031CM output until the controller supply returns. Looking only at OUT could make expected output disable look like a startup failure. This active oscillator has separate supplies for the oscillation circuit and output buffer. Identify which supply is switched to understand both sleep current and the required time to the first usable pulse.
Follow the two supply pins
Epson’s SG-3031CM/SG-3031CMA specification identifies pin 4, VCC, as the oscillator supply and pin 1, VIO, as the output-side supply. Pin 3 is OUT. VIO can disable the output when set to zero according to the specification. It should not be wired as an arbitrary logic enable just because pin 1 on some other oscillator serves that function. If an old part left pin 1 open, review wiring and decoupling before approving a substitute. Purchasing should request the exact part number and pin function in addition to 32.768 kHz and the package dimensions.
Epson describes the oscillation circuit remaining in operation when VIO is zero and VCC is maintained. When output power returns, the circuit need not undergo an entirely new oscillator start. Still measure when the receiving circuit gets a valid first waveform. Rail ramp, receiver thresholds, and controller reset affect when the board can use the clock. When VCC also turns off, test against the cold-start requirements. These are separate bench tests even if firmware calls both states “sleep.”
Calculate the capacitive load contribution
Suppose the output supply is 3.0 V and the load is approximately 10 pF. Multiplying 32,768 Hz by 10 pF and 3.0 V estimates about 0.983 µA of average capacitive charging current. At 5 pF the result is about 0.492 µA. These estimates cover only capacitive loading. They do not include the oscillator core, buffer quiescent current, other board components, or resistive paths drawing current from that supply.
Epson distinguishes current at VCC and VIO and describes the load component. Check whether an output-supply measurement under load already includes charging the capacitor. If an ammeter measured the whole loaded rail, do not add the estimated 0.983 µA again. If a supplier reports only a no-load value, review the load contribution separately. For battery-energy estimates with different rail voltages, use voltage × current × time for each rail and account for the applicable conversion losses.
Capture output re-enable and cold start separately
For the first test, maintain VCC at its operating condition and disable and restore VIO as supported. Observe both rails and the 32.768 kHz waveform at the receiver. Trigger on VIO restoration and record when the rail is usable and when a valid high and low are first present. If the controller wakes at the same time, add its reset-release signal to distinguish invalid thresholds, a controller not yet ready, and an oscillator that has not provided the clock.
For the second test, reproduce a complete power loss. If VCC is removed, measure true oscillator startup and both rail ramps. The specification includes conditions for lower VCC, such as requiring VIO to equal VCC for normal output when VCC is at least 1.2 V but below 1.5 V. If the next revision lowers the keep-alive rail, review the applicable condition before reusing the separately switched output scheme. Do not assume that an example from a higher supply applies in the lower-voltage build.
The specification lists a 0.45 s maximum cold startup at the stated higher VCC and temperature conditions. At the nominal frequency, that is an elapsed time of about 14,746 periods. The conversion does not count pulses emitted during startup and does not predict time to output when restoring VIO alone. If the project needs an earlier clock, document which rails actually turned off. Compare both waveforms at the same receiving threshold before changing the power sequence or firmware wait.
Check amplitude at the receiver as well. For example, under the relevant specified output current, a 3.0 V output supply minus the allowed 0.4 V gives 2.6 V. A receiver threshold of 2.3 V would leave 0.3 V on paper, before wiring loss, noise, and supply variation. Measure at the receiving pin.
Qualify the power state as well as the part
For purchasing, record the complete ordering code, oscillator supply, intended output level and load, and pin 1 function. If system timekeeping during sleep is required, establish which circuit remains powered and which device receives the clock. A running internal oscillator, a clock at the external pin, and a time counter that continues running are separate conditions. Seeing the output after wake does not establish what the RTC received before wake.
Keep separate results for continuous output, disabled output with VCC held, and full power loss. If the clock disappears, inspect both power rails before blaming the oscillator or the receiver. If the power report gives a single sleep current, document where it was measured and what other circuits share that rail. This provides reproducible evidence for both fault isolation and same-frequency oscillator substitution.