The oscillator starts normally on a slow bench ramp, but a load switch applies power abruptly in production. Matching final voltage alone does not reproduce the same condition. An Epson SG3225CAN configuration datasheet specifies more than 150 µs from 0% to 90% VCC in its test circuit. That is a test condition. It does not guarantee operation at every faster ramp.
Measure at the device pads rather than copying regulator specifications
Capture the supply and control pins relative to ground on the actual board. Mark the start of the ramp, the 90% point, the first valid clock and receiver reset release. Bench-supply settings do not describe the waveform after connectors, load switches and local capacitors. Verify whether the supply actually reaches zero before a rapid restart. Keep residual-voltage and cold-start records separate.
Separate factory inspection from system reproduction
Use one entry for incoming inspection under the exact datasheet conditions, with the supply ramp and measurement location. Use a second for board verification over the system's fastest and slowest power ramps. Ask the supplier whether written specifications apply outside the published test conditions. If only sample results are available, document sample count, board revision and environment without extending them to the series.
If the fix is soft start or revised enable timing, record it in the supply or firmware change. Approval is for an exact part and operating envelope. If the load switch changes later, engineering will know which waveform to check again. Epson SG3225CAN output test and supply conditions