Two oscillators both specify ±0.5% center spread, yet one peak differs in an EMI prescan. Epson's SG-9101 table separates spread direction, depth, modulation rate and waveform, including sine and triangle options. Equal depth means an equal frequency span. The movement within that span can still differ. Keep the waveform option used on the engineering sample in the production RFQ.
Write out both types of frequency to avoid confusion
Record the output base or center clock frequency separately from the modulation repetition rate, which the manufacturer's table gives in kHz. Also record spread direction and width. If another chip can spread the clock, determine which one modulated the trial so enabling both does not invalidate comparisons. Manufacturer illustrations explain options. They do not guarantee a specified dB reduction at a particular system frequency.
Change only one option in the comparison
Keep routing, shielding, cables and receiver settings alike, and hold modulation depth and repetition rate constant while comparing waveforms. Record changes in detector, resolution bandwidth or antenna position so test changes are not attributed to the device. Check that sensitive receivers can still lock and operate with spreading enabled.
Give purchasing the complete configuration, sample serial number, operating conditions and report ID after acceptance. A later waveform change with unchanged center frequency and depth still warrants review. Epson SG-9101 spread spectrum options and comparison figures