When choosing a reference for an Si47xx radio, a headline RCLK range from roughly 30 kHz to several tens of megahertz can make every intermediate frequency look valid. Skyworks AN332 requires the prescaled reference to fall between 31130 and 34406 Hz and asks for the actual frequency to be written to the reference-frequency property. The divider is an integer, which leaves gaps between valid input bands, especially at low divider values.
Find a valid integer divisor before reusing an existing oscillator
An available 4.096 MHz oscillator is easy to check. Dividing by 125 gives 32768 Hz. According to the manufacturer’s table, the input window for a divisor of 1 ends at 34406 Hz. The next window, for a divisor of 2, starts at 62260 Hz. A 50000 Hz input is too high with a divisor of 1 and too low with a divisor of 2. It falls within the headline limits but meets neither of these adjacent configurations.
Record the actual input frequency, the prescaler value, and the resulting divided frequency in the design table. If the result is 32500 Hz, enter that value as required by the manual. A frequency near the standard watch-crystal value does not justify entering 32768. Verify that the exact radio IC and the feature in use support this property. Firmware and wiring vary across the Si47xx family.
Verify tuning and automatic frequency control near a fixed station with a known reference before switching to the shared source. The manufacturer specifies when the reference must remain valid around tuning commands and while AFC is active. Include host sleep in the test if it can stop the shared clock. Record the source frequency and whether it runs continuously in the purchase specification. Keep the corresponding integer divisor in the firmware record so the reference configuration can be reproduced.Skyworks Si47xx programming guide AN332