Suppose the Si5341 setup screen shows a change to OUT3 from 125 MHz to 100 MHz, and a second acquisition clock drops from 250 MHz to 200 MHz at the same time. The two ratios, 100 ÷ 125 and 200 ÷ 250, both equal 0.8. That points to a possible change in a shared clock source. To confirm it, compare the actual output routing and divider values with the timed register writes. The board conditions and frequencies below are worked examples.
Read the crosspoint before changing a divider
The Si5341 Rev D has five N dividers, N0 through N4. OUT3 has a dedicated R3 divider, and the output crosspoint selects which N drives it. On the Si5341, look up OUT3_MUX_SEL at 0x011A[2:0] in Section 5.4 of the reference manual. Read the assignment from the loaded configuration, then check every other used output for a connection to that N. Add the board destination to the list. A clock that appears to serve one interface may also reach a board connector or the controller responsible for writing the clock registers.
For the examples below, assume a Si5341A-D configured for differential outputs, internal feedback and a fixed 14,000 MHz VCO. The reference input and PLL settings stay fixed. The steady-state output frequency is VCO frequency ÷ N ÷ R. With N1 set to 28, its output is 500 MHz. OUT3 divides that by four to get 125 MHz, and OUT7 divides it by two to get 250 MHz. As a control, OUT0 takes 400 MHz from N0 set to 35 and divides it by four to get 100 MHz. If the board uses zero-delay mode, first check which output comes back through FB_IN. That output is part of the PLL feedback path, so the fixed-VCO examples here apply only under the stated conditions.
Four changes starting from the same frequency plan
| Proposed change | OUT3 | OUT7 | OUT0 |
|---|---|---|---|
| Baseline with OUT3 and OUT7 on N1 | 125 MHz | 250 MHz | 100 MHz |
| Change R3 from 4 to 8 for 62.5 MHz on OUT3 | 62.5 MHz | 250 MHz | 100 MHz |
| Change shared N1 from 28 to 35 and keep R3 and R7 at 4 and 2 | 100 MHz | 200 MHz | 100 MHz |
| Route OUT3 to the existing N0 and keep R3 at 4 | 100 MHz | 250 MHz | 100 MHz |
| Assign an available N2 to OUT3, set N2 to 112/5 and keep R3 at 4 | 156.25 MHz | 250 MHz | 100 MHz |
Divide the current N output of 500 MHz by the requested OUT3 frequency to see whether R3 alone can do the job. At 62.5 MHz the quotient is 8. At 100 MHz the quotient is 5. The R stage supports only even divisors, from 2 through 225−2. On the Si5341, R3 is at 0x0253–0x0255. With OUT3_RDIV_FORCE2 clear, divide-by-4 uses R3_REG = 1 and divide-by-8 uses R3_REG = 3, following R = 2 × (R3_REG + 1). Divide-by-2 uses the force bit. A zero register value with the force bit clear disables the divider. Decode the force bit alongside the register value when reading back an existing configuration.
Changing N1 to 35 for a 400 MHz branch brings OUT3 to 100 MHz. Keeping OUT7 at 250 MHz would require R7 = 400 ÷ 250 = 1.6, which the R stage cannot supply. Routing OUT3 to the existing N0 gives OUT3 its 100 MHz target while preserving OUT7 at 250 MHz. OUT0 now shares its N divider with OUT3. Account for both outputs the next time N0 needs retuning. If OUT3 needs a separate tuning path, check for a free N. For 156.25 MHz with R3 fixed at 4, the branch must supply 625 MHz, so N2 = 14,000 ÷ 625 = 112/5. Applying that same ratio to shared N1 would put OUT7 at 312.5 MHz. Check the candidate plan in ClockBuilder Pro for available N resources, device grade, output format, supply and phase requirements.
Find the write that made the new ratio effective
Each N divider supports ratios from 10 through 4095, represented by a 44-bit numerator and a 32-bit denominator. Suppose the loaded N1 denominator is 231. A divide value of 28 then uses a numerator of 60,129,542,144. Holding that denominator and changing the divide value to 35 requires 75,161,927,680. Use the actual denominator when you calculate the numerator. ClockBuilder Pro scales the two terms to make use of the available register widths.
After writing N1's new value, a write to N1_UPDATE at 0x0317[0] commits it. The global N_UPDATE at 0x0338[1] can also commit changes pending on other N dividers. The manual specifies writing zeros to the other bits of that byte when requesting the global update. Inspect the order of operations in the bus log to see which values were staged at that point. A diff of the final register values may miss a mute, reset or update pulse that was issued and cleared during a full configuration load.
Section 6.1.2 of the reference manual describes glitchless frequency changes when updating the N numerator through the specified DCO procedure. Fractional operation requires the corresponding N_PIBYP bit to be clear. If the application uses FINC or FDEC, check N_FSTEP_MSK as well, since a step can affect more than one unmasked N divider. The manual flags a possible phase change of about 550 fs when the denominator is changed and directs users who need that operation to Skyworks Support. Qualify changes to R, crosspoint routing and full configuration loads separately. If the generated plan also changes the PLL settings, use the revision-specific procedure in Section 7 and account for calibration, relock and receiver recovery.
Capture the two affected candidates and a control output
Trigger on the decoded I²C or SPI transaction, or mark the update in firmware with a synchronized trigger signal. Put OUT3, OUT7 and OUT0 on the same capture. Record the baseline and final frequencies, then zoom into the change at the receiver. The periods at 125, 100 and 62.5 MHz are 8, 10 and 16 ns respectively. A frequency counter can confirm the steady states. To see what the receiver experienced during the switch, use its applicable threshold and measure the shortest high and low pulses, the longest interval between active edges, and the time to resume valid clocking.
| Capture shows | Evidence to check next |
|---|---|
| OUT3 reaches 100 MHz, OUT7 reaches 200 MHz and OUT0 stays at 100 MHz. | This fits an N1 change from 28 to 35. Confirm both crosspoint assignments and line up the changes with the N1 update write. |
| The new N parameters read back, while both outputs remain at their original frequencies. | Check the bus page and address, the order of the writes, the update action and the N currently selected by each output. |
| OUT0 also pauses and then resumes at 100 MHz. | Correlate the gap with global and per-output enables, OEB, and reset writes. Check calibration and loss-of-lock status, and compare sticky flags before and after the test to investigate events that can end between polls. |
| The clock returns, but the acquisition interface fails to resume. | Check receiver lock, reset release and data recovery. Measure the phase relationship again if the receiver depends on timing between outputs. |
Before the test, agree on the allowed clock gap, minimum pulse widths, receiver lock conditions and any phase limits. If the receiver tolerates an interruption, pause traffic or hold it in reset before switching, then follow its recovery sequence after the clock stabilizes. If a processor or programming interface uses a clock under test, set up an independent management path and check that it can reload the previous configuration. Retain the bus trace, clock capture and receiver state from the same run so that cold boot, live update and rollback can be compared.
Release the frequency plan with the exact ordering code
The Rev D ordering guide lists Si5341A/B for integer and fractional synthesis and Si5341C/D for integer synthesis. It lists a 350 MHz maximum for B/D and 1028 MHz for A/C, subject to output-format limits in the electrical specifications. The custom ordering code identifies a particular factory-programmed configuration. Keep the full ordering code with the ClockBuilder Pro project, register-script revision and a per-output list of the selected N, effective R, output format and expected frequency. When qualifying a substitute or a configuration revision, use that record to check both cold-start clocks and the transition at each receiver that depends on a shared divider.
