Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

Why can Si5345 zero-delay settings disappear after reset while the 50 MHz oscillator keeps running?

A Si5345 supplies a 156.25 MHz output. After enabling zero-delay mode, the firmware requests a hard reset and immediately writes the operating configuration. The initial readback matches. Less than a second later, outputs return to their default frequencies or turn off. The board's 50 MHz oscillator continues to run. Begin with the time at which the reset actually executes and the time at which the software writes the configuration. The term zero delay describes a feedback mode for the clock path. Reset and recovery have their own timing.

Trace three separate paths

The Si5345 documentation treats the local XA/XB reference and the DSPLL synchronization inputs separately. In an example board, a 50 MHz oscillator feeds the local reference using the manufacturer's input circuit, while a system clock feeds IN0. In zero-delay mode an output also loops back to FB_IN. A valid local oscillator waveform leaves two checks open. Verify the selected synchronization input and the actual feedback route.

If one board uses a 50 MHz passive quartz crystal and another uses an active oscillator, compare their schematics and loaded components. Skyworks shows different reference circuits for a crystal, a differential external clock and a single-ended LVCMOS source. Check the coupling and bias network, and measure the signal near the receiver. Be aware that probing the pins of a passive crystal can change the oscillator behavior.

With zero-delay mode enabled, IN3 becomes FB_IN and is unavailable as a fourth synchronization input. The Si5345 documentation recommends OUT9 as a practical feedback source and describes the required AC coupling and termination. Differential feedback is preferred. Review the specific part, output format and routed connection before interpreting an apparently correct output frequency.

Wait for the hard reset to execute

Section 7 of the Rev D reference manual describes a delay of approximately 750 ms before a hard reset request executes in zero-delay mode. It applies to a request from RSTb or RST_REG. If software writes the operating configuration too soon, the subsequent reset can overwrite it with the device's nonvolatile settings. A correct immediate readback shows what was present at that moment. Keep another record after the reset window before deciding the local oscillator is faulty.

Suppose firmware requests reset at time zero, writes settings at 200 ms and the reset executes at about 750 ms. The write precedes the reset by about 550 ms. If software polls every 100 ms, the observed transition can be localized only to the interval between two polls. Treat these numbers as an example. Approximately 750 ms is not a system-level maximum. Define the actual wait and completion detection using the device documentation and the product's validation conditions, including temperature and supply.

Align the scope and the firmware log

Capture the local reference, feedback, control interface and output in a repeatable test. Trigger on RSTb or a spare debug signal that the firmware toggles when it sends the command. Retain the previous configuration, initial readback, readback after the nonvolatile settings are loaded and the final readback after writing the operating values. Use a shared trigger so that traces from different instruments can be compared on the same time base.

Then check the receiver that actually consumes the clock. Record the time from reset to usable clock, the relative phase and any momentary interruption. At 156.25 MHz the nominal period is 6.4 ns, a useful reference for interpreting a phase measurement. If data loss occurs only during recovery, verify clock and reset release order. If the steady phase fails the requirement, investigate feedback and the path to the real receiver. Skyworks also specifies that its hitless switching feature is unavailable in zero-delay mode. A design with redundant sources should therefore qualify its switching behavior against the actual application limits.

For a controlled comparison, retain the same oscillator and feedback configuration. Write early in one run and wait for verified reset completion in the other. If the default values reappear only in the early-write run, that is better evidence of an ordering problem than a frequency plot alone. If recovery fails in both runs, check the selected synchronization input and feedback amplitude against the configuration that actually loaded.

Procurement should retain the 50 MHz oscillator's complete order number, output logic, supply voltage and tolerance. Engineering should record the clock IC revision, nonvolatile configuration version, feedback routing and reset recovery traces. If the fault follows an early register write, correct the startup sequence before opening a clock-source change request. If it follows an oscillator lot with a fixed sequence, the records give the team a place to begin the component comparison.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.