A measurement board uses an Si5351A to supply two clocks for sampling at quarter-cycle intervals. A frequency counter shows about 10 MHz at each test point, but their edges nearly coincide on an oscilloscope. Restarting can change what the operator sees. Measure each output against an independent frequency reference and capture the separation between like edges on the same timebase. A 25 MHz quartz crystal affects the absolute frequency of both synthesized outputs. Output paths, initial phase offsets and reset sequencing also determine their relative alignment.
Calculate a quarter cycle from the output
A 10 MHz period is 100 ns, so a quarter cycle is 25 ns. The phase register uses one quarter of the internal VCO period per step. Suppose a 25 MHz crystal is multiplied by 32 to obtain 800 MHz. The internal period is 1.25 ns and its quarter is 0.3125 ns. Dividing the VCO frequency by 80 gives 10 MHz. In this example the programmed offset can be 0 on one output and 80 on the other, with two independent MultiSynth paths fed by the same PLL and the relevant forced integer mode disabled. Check the actual sign at the receiving pins using matching edges.
Writing 25 to the register would program 7.8125 ns, about 28 degrees. A later revision might use a 900 MHz PLL and divide by 90 for the same 10 MHz output. Each phase step would then be about 0.2778 ns. Keeping an offset code of 80 gives about 22.22 ns, or 80 degrees. Recompute the phase register whenever the VCO frequency changes. Keep the rounding error in the phase budget. For the package variants covered here, the individual register descriptions specify seven offset bits and require the highest bit to remain clear.
Read back each output path
For the parts covered by AN619, check the CLK0 and CLK1 output controls. Each path needs its intended output divider, and the two dividers need the planned common PLL source. CLK1 also has a source option that routes MultiSynth 0 to its output. If both channels accidentally use that path, changing the settings of MultiSynth 1 will fail to produce the expected measurement. Read the actual source bits, especially when a library generates the register image. A numerical divide ratio of 80 is also compatible with using the fractional divider path. AN619 calls for clearing MSx_INT when applying the phase offset.
Keep downstream logic in its appropriate wait state during initialization. Follow the vendor startup sequence for the actual device and check SYS_INIT, program the dividers and offsets, reset the affected PLL and enable the outputs according to the board's dependencies. A controller restart can leave the clock chip powered with its previous settings intact. Qualify cold power-on and software restart separately. Correlate the startup, lock status, output enable and downstream capture events on one record.
Measure static offset and slow phase motion
Feed the same reference edge to both oscilloscope channels to characterize probe and channel mismatch. Then compare like edges with the same threshold convention, preferably at the real receiver. Drive strength, routing and unequal loading can shift the time at which a signal crosses a threshold. If a threshold changes by 0.1 V and the local edge slope is 0.5 V per ns, the crossing shifts by about 0.2 ns, equivalent to 0.72 degrees at 10 MHz. Account for that when the phase allowance is small.
Observe many cycles. A consistently repeatable separation near 22 ns points toward a phase setting or VCO frequency check in this example. Continuous motion calls for checking the selected references, lock history and trigger setup. For comparison, if two independent active 10 MHz oscillators differ by 20 Hz, their relative phase slips through a full cycle about once every 50 ms. Capture enough time to distinguish systematic phase motion from a fixed offset. Agree on the expected leading output and the phase tolerance before accepting parts or a new register file.
Prepare a control configuration that changes only the phase code. With the 800 MHz VCO, change the second code from 80 to 40, reinitialize the affected path as specified and let the clock settle. The expected separation changes from 25 ns to 12.5 ns while frequency remains 10 MHz. An unchanged separation helps narrow the investigation to register updates and output routing. Make this test during an approved stop window if downstream logic requires a continuous clock.
Procurement can retain full crystal part number, load capacitance, temperature limits and drive allowance. Engineering can retain the installed Si5351 package, tools and actual register values, including the enabled internal crystal load setting. An active reference uses an input connection and electrical levels supported by the specific clock-generator variant. Repeat both absolute-frequency and relative-phase measurements after such a redesign. A common frequency error points toward the reference and its loading. If both outputs have the intended frequencies and their phase is consistently wrong, inspect the output paths and offset calculation before buying a tighter crystal.