Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

Why does the Si5351 crystal table list 100 µW in the minimum column?

When sourcing a 25 MHz crystal for an Si5351 clock generator, the data sheet puts 100 µW in the Min column for Crystal Max Drive Level. Read this as a required rating for the candidate: the crystal needs a maximum permitted drive of at least 100 µW. During use, the board needs to start the crystal reliably and keep actual dissipation within the selected part's limits. Entering 100 µW as a required operating dissipation would confuse those responsibilities.

This interpretation refers to Table 8 of Skyworks' Si5351A/B/C-B Rev. 1.3 data sheet for a passive crystal at XA and XB. Check the installed chip's complete code and reference configuration before applying the table. An active reference uses the relevant external-clock input requirements. The CLK output drive setting belongs to the output interface. Skyworks Si5351A/B/C-B data sheet, Table 8.

Record three different power values in the RFQ

First comes the host's requirement for a crystal rating. Second comes the crystal manufacturer's rating for the exact order code. A typical drive figure such as 10 µW may belong to factory measurement or characterization. Ask the supplier what the figure applies to and request the maximum permitted drive for the same part. The third quantity is the actual power dissipated by that crystal on the board in the selected configuration.

Suppose two candidates have the same package and frequency but allow maximum drive of 50 µW and 100 µW, respectively. The 50 µW part misses the rating requirement even if a prototype test happened to dissipate only 40 µW. The 100 µW part meets this one screening criterion. Its load specification, ESR, pinout and operating temperature still need evidence. A quotation giving only a typical 10 µW figure leaves its maximum-rating field unresolved.

Convert the measured current using the matching resistance definition

One method documented by NDK uses the RMS crystal-terminal current I and the load resonant resistance RL to estimate P = I² × RL. If the available parameters are motional resistance R1, shunt capacitance C0 and load capacitance CL, its method uses RL = R1 × (1 + C0 ÷ CL)². Keep the current measurement definition consistent with the resistance. If the maker already supplied RL for this condition, use that definition directly to avoid counting the load effect twice.

For a hypothetical crystal with R1 = 50 Ω, C0 = 2 pF and CL = 8 pF, RL is 78.125 Ω. At 0.80 mA RMS, estimated power is 50.0 µW. At 1.20 mA RMS, estimated power is 112.5 µW. Relative to a crystal rated at 100 µW, these two tests leave 50 µW of headroom and exceed the rating by 12.5 µW, respectively. Increasing current by a factor of 1.5 multiplies power by 2.25. NDK oscillator circuit evaluation, drive-level calculation.

Record whether the instrument reports RMS, peak or peak-to-peak. For an approximately sinusoidal signal, 1.20 mA peak-to-peak corresponds to about 0.424 mA RMS. With the same resistance, that would be about 14.1 µW, one eighth of the result for 1.20 mA RMS. If the probe changes the oscillation, or if a startup waveform is distorted, agree on a measurement method and decision rule with the crystal manufacturer.

Qualify startup and the load setting separately

Table 8 also lists 6–12 pF for crystal load and 150 Ω for maximum ESR. Match the definition in the crystal documentation to the host requirement. Its footnote recommends using the device's internal load for 6, 8 or 10 pF crystals and describes a combination of internal and external capacitance for the 12 pF case. Inspect the actual configuration before assuming a value on the schematic is the load the crystal sees.

Skyworks AN551 describes a high-gain startup stage and a normal-gain sustained stage for the Si5350/51 oscillator. Check startup from a fully discharged board. For scale, if the series-resistor method gives a critical added resistance of 300 Ω and the applicable ESR is 78.125 Ω, the AN551 safety factor is (300 + 78.125) ÷ 78.125 = 4.84. That falls below the guide's value of 5. Resolve the startup margin and verify sustained operation even if a separate drive measurement passes. Skyworks AN551, oscillator gain and startup test method.

When a system clocks late, identify the source of the observed CLK output, check PLL lock, and record when firmware enables the output. Crystal startup, PLL lock and the first usable application clock can be separate events. Test an approved crystal in the same configuration if you need a baseline for a candidate.

Keep the host code and data-sheet revision, crystal part number, load configuration, applicable ESR and maximum drive rating together with the report. Include supply and temperature conditions, the startup criterion and measured dissipation. If procurement is offered another 25 MHz part, the report shows exactly what evidence to request before engineering starts a comparison.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.