Two Si570s drive different modules. A prototype with just one works. If both production devices use the same address on one I²C bus, the host cannot readily configure them independently. The manufacturer's FAQ says the factory programs power-up frequency and I²C address in nonvolatile memory. Specify both when requesting a part number. Runtime access to frequency registers does not mean the factory address can be rewritten after assembly.
Say whether an address is seven bits or includes the read/write bit
Ask firmware to map other bus devices and addresses and indicate whether each datasheet uses a seven-bit value or a transmitted byte that includes the read/write bit. One address can appear as two different hex values. Normalize the notation before comparison. Specify each position's default address and power-up frequency separately and request the matching factory configuration or complete order code rather than listing only “two programmable Si570s.”
Populate both positions on a qualification sample
Reset the actual circuit, read or configure each device separately and monitor its clock output. Include a cold power-up and changes to the configuration order so temporary register settings left on a debug board do not hide a problem. If only one address is available, assess bus isolation, a switch or separate control interfaces and account for the related BOM and firmware changes.
Map each order code to one assembly designator and label the two codes separately through receiving and kitting. If the correct parts are reversed, both may still respond on the bus but frequency changes affect the wrong module. Final acceptance must check the address against the physical output it controls. Si570 and Si571 manufacturer FAQ