Firmware may fine-tune an Si570 by only a few dozen ppm per write. After many writes, the steps can remain small while the output no longer qualifies for the uninterrupted small-change procedure. Table 11 defines the continuous range around a center frequency. Firmware needs to retain that center instead of treating every newly written frequency as a new center.
Track cumulative offset in the sweep table
Suppose a large reconfiguration sets the center frequency to 100 MHz. The continuous adjustment range of ±3500 ppm is approximately ±350 kHz. Moving to 100.30 MHz stays within the range, while 100.40 MHz exceeds its upper limit. Even a final step of only 10 kHz must follow the large-change procedure if it crosses the limit. Also check the divider settings and internal oscillator frequency against the limits for the target configuration.
The manual specifies separate settling times for small and large frequency changes. A settling time does not guarantee that the output stays within the receiver’s tolerance during the entire transition. If the receiver clock cannot be interrupted, place the working center near the middle of the adjustment range and calculate margin at both ends. If the sweep must cross the boundary, consider redefining the center while acquisition is paused.
Sweep from the negative end to the positive end, then reverse the path. Record every command, the center frequency, and how boundary crossings are handled. Use continuous acquisition to check edges and any downstream loss-of-lock indicator together. After power loss, the device returns to its factory startup frequency, so software should rebuild the center state before resuming tuning.Skyworks Si570/Si571 manual, Table 11 and reprogramming instructions